========================== QD21 DISK CONTROLLER =============================
                             TECHNICAL MANUAL
                             (MSCP COMPATIBLE)
                      QD2151002-00 Rev G  June, 1989

                 ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                 ³ EMULEX PRODUCT/MANUAL REVISION HISTORY ³
                 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

                      PROM E65x(1), Location U44

           ÚÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
           ³PROM E65x³ DESCRIPTION          ³ MANUAL P/N    ³
           ÃÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
           ³A,B,C,D  ³ QD21 with            ³ QD2151001-00, ³
           ³         ³ optional diagnostics ³               ³
           ³         ³                      ³               ³
           ³E and    ³ QD21 with firmware-  ³ QD2151002-00  ³
           ³above    ³ resident diagnostics ³               ³
           ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


This manual has been extensively revised to incorporate changes to support the 
Firmware-Resident Diagnostics (F.R.D.) that have been added to the Revision E
controller firmware PROM. Due to the nature of these firmware changes, a QD21
with a Revision E and above firmware PROM will no longer operate with 
previously supplied diagnostic software. In addition, some of the ODT functions
(NOVRAM loading commands and Format Drive command) previously available are no
longer available.

All of the functionality that was provided by software diagnostics and ODT 
commands has been incorporated in F.R.D.  Be certain that your manual is 
appropriate for the revision level of your controller firmware, as noted in the
table above.  This firmware is easily identified by the label at U44.

   WARNING

     This equipment generates, uses and can radiate radio frequency energy,
     and if not installed and used in accordance with the technical manual,
     may cause interference to radio communications.  It has been tested and
     found to comply with the limits for a Class A computing device pursuant
     to Subpart J of Part 15 of Federal Communications Commission (FCC)
     Rules, which are designed to provide reasonable protection against such
     interference when operating in a commercial environment.  Operation
     of this equipment in a residential area is likely to cause interference in
     which case the user at his own expense will be required to take whatever
     measures may be required to correct the interference.

Copyright (c) 1988 Emulex Corporation

The information in this manual is for information purposes and is subject to 
change without notice.

Emulex Corporation assumes no responsibility for any errors which may appear in
the manual.

Printed in U.S.A.

(1) The small x indicates the PROM's revision level letter: A, B, C, etc.
                                             
                         ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                         ³ TABLE OF CONTENTS ³
                         ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

ONE             INTRODUCTION
----------------------------
1.1             OVERVIEW
1.2             SUBSYSTEM OVERVIEW
1.2.1               Mass Storage Control Protocol (MSCP)
1.3             PHYSICAL ORGANIZATION OVERVIEW
1.4             SUBSYSTEM MODELS
1.5             FEATURES
1.5.1               Microprocessor Design
1.5.2               Firmware-Resident Diagnostics
1.5.3               Custom Configuration Capability
1.5.4               Self-Test
1.5.5               Error Control
1.5.6               Host-Initiated Bad Block Replacement
1.5.7               Seek Optimization
1.5.8               Command Buffer
1.5.9               Adaptive DMA
1.5.10              Block-Mode DMA
1.5.11              Twenty-Two-Bit Addressing
1.6             COMPATIBILITY
1.6.1               Operating Systems
1.6.2               Hardware

TWO             CONTROLLER SPECIFICATION
----------------------------------------
2.1             OVERVIEW
2.2             GENERAL SPECIFICATION
2.3             ENVIRONMENTAL SPECIFICATION
2.4             PHYSICAL SPECIFICATION
2.5             ELECTRICAL SPECIFICATION

THREE           PLANNING THE INSTALLATION
-----------------------------------------
3.1             OVERVIEW
3.2             MSCP SUBSYSTEM CONFIGURATION
3.2.1               Architecture
3.2.2               Peripheral Numbering
3.2.3               Peripheral Capacities
3.3             A DEC MSCP SUBSYSTEM
3.4             THE QD21 MSCP SUBSYSTEM
3.4.1               Logical Unit Numbers
3.4.2               QD21 MSCP Subsystem Logical Configuration
3.4.2.1                 Logical Devices
3.4.2.2                 Device Numbers
3.5             OPERATING SYSTEMS, DEVICE AND VECTOR ADDRESSES
3.5.1               RSTS/E Operating Systems (V8.0 and above)
3.5.1.1                 Adding MSCP Support
3.5.2               Operating Systems (V5.1 and above)
3.5.2.1                 Installing a Single MSCP Controller
3.5.2.2                 Installing Multiple MSCP Controllers
3.5.2.3                 Disk Partitioning
3.5.3               RSX-11M Operating Systems (V4.0 and above)
3.5.3.1                 Installing a Single MSCP Controller
3.5.3.2                 Installing Multiple MSCP Controllers
3.5.4               RSX-11-MPlus Operating Systems (V2.1 and above)
3.5.4.1                 Installing a Single MSCP Controller
3.5.4.2                 Installing Multiple MSCP Controllers
3.5.5               MicroVMS Operating Systems
3.5.6               Ultrix-11 Operating Systems (V3.0 and above)
3.5.6.1                 Sysgen
3.5.6.2                 Special Files
3.5.6.3                 Newfs
3.5.6.4                 Volcopy
3.5.6.5                 Copying a Bootstrap
3.5.7               Ultrix-32 Operating Systems
3.5.7.1                 The Kernel
3.5.7.2                 Special Files
3.5.7.3                 Autoconfigure
3.5.7.4                 Disk Partitions
3.5.7.5                 Disk Partition Modifications
3.5.7.6                 Default Partition Modifications
3.5.7.7                 Newfs
3.5.7.8                 Suggestions/Warnings
                
FOUR            INSTALLATION
----------------------------
4.1             OVERVIEW
4.1.1               Subsystem Configurations
4.1.2               Dip Switch Type
4.1.3               Maintaining FCC Class A Compliance
4.2             INSPECTION
4.3             DISK CONTROLLER SETUP
4.3.1               Disk Controller Bus Address
4.3.2               Interrupt Vector Address
4.3.3               Options
4.3.3.1                Automatic Bootstrapping
4.3.3.2                MSCP Device Number
4.3.3.2.1              Logical Unit to Boot From
4.3.3.2.2              First Logical Unit Number for an Alternate Address
4.3.3.3                22-Bit Memory Addressing
4.3.3.4                DMA Burst Delay
4.3.3.5                DMA Adaptive Mode
4.4             PHYSICAL INSTALLATION
4.4.1               System Preparation
4.4.2               Slot Selection
4.4.3               Mounting
4.5             ESDI DISK DRIVE PREPARATION
4.5.1               Drive Placement
4.5.2               Sectoring
4.5.3               Drive Numbering
4.5.4               Spindle Motor Spin-up
4.5.5               Termination
4.6             CABLING
4.7             NOVRAM LOADING, DISK FORMATTING, AND TESTING
4.7.1               F.R.D. Conventions
4.7.2               Starting F.R.D. on a MicroVAX I
4.7.3               Starting F.R.D. on a MicroVAX II and a GPX Workstation
4.7.4               Starting F.R.D. on an LSI-11 System
4.7.5               Terminating F.R.D
4.8             F.R.D. OPTIONS
4.8.1               Option 1 - Self-test Loop
4.8.2               Option 2 - Format
4.8.3               Option 3 - Verify
4.8.4               Option 4 - Format and Verify
4.8.5               Option 5 - Data Reliability Test
4.8.6               Option 6 - Format, Verify, and Data Reliability Test
4.8.7               Option 7 - Read Only Test
4.8.8               Option 8 - List Known Units
4.8.9               Option 9 - Replace Block
4.8.10              Option 10 - Display NOVRAM
4.8.11              Option 11 - Edit/Load NOVRAM
4.9             DRIVE CONFIGURATION PARAMETERS
4.9.1               Type Code
4.9.2               Number of Units of this Type
4.9.3               Number of Sectors per Track
4.9.4               Number of Heads
4.9.5               Number of Cylinders
4.9.6               Number of Spare Sectors per Track
4.9.7               Number of Alternate Cylinders
4.9.8               Configuration Bits
4.9.9               Split Code
4.9.10              Cylinder Offset
4.9.11              Starting Head Offset
4.9.12              Removable Media               
4.9.13              Gap 0, 1, and 2 Parameters
4.9.14              Spiral Offset
4.10            OPERATION
4.10.1              Indicators

FIVE            TROUBLESHOOTING
-------------------------------
5.1             OVERVIEW
5.2             SERVICE
5.3             FAULT ISOLATION PROCEDURE
5.4             POWER-UP SELF-DIAGNOSTIC
5.5             FATAL ERROR CODES

SIX             DEVICE REGISTERS AND PROGRAMMING
------------------------------------------------
6.1             OVERVIEW
6.2             OVERVIEW OF MSCP SUBSYSTEM
6.3             PROGRAMMING
6.3.1               MSCP Command Support
6.3.1.1                Minimal Disk Subset
6.3.1.2                Diagnostic and Utility Protocol (DUP)
6.4             REGISTERS
6.5             BOOTSTRAP COMMAND

SEVEN           FUNCTIONAL DESCRIPTION
--------------------------------------
7.1             OVERVIEW
7.2             QD21 DISK CONTROLLER ARCHITECTURE

EIGHT           INTERFACES
--------------------------
8.1             OVERVIEW
8.2             LSI-11 BUS INTERFACE
8.2.1               Interrupt Priority Level
8.2.2               Register Address
8.2.3               DMA Operations
8.2.3               Scatter/Gather
8.3             QD21 ESDI DISK DRIVE INTERFACE
8.4             FRONT PANEL INTERFACE

APPENDICES
A               AUTOCONFIGURE, CSR AND VECTOR ADDRESSES
-------------------------------------------------------
A.1             Overview
A.2             Determining the CSR Address for Use With Autoconfigure
A.3             Determining the Vector Address for Use With Autoconfigure
A.4             A System Configuration Example

B               PROM REMOVAL AND REPLACEMENT
--------------------------------------------
B.1             Overview
B.2             Exchanging Proms

C               DISK DRIVE CONFIGURATION PARAMETERS
---------------------------------------------------
C.1             Overview
C.2             Parameter Values
C.3             Recommended Drive Options
C.3.1             Setting the Switches on the CDC Wren III

LIST OF FIGURES
---------------
1-1          QD21 Subsystem Configuration
1-2          QD21 Disk Controller
1-3          Sales Order Example
2-1          QD21 Disk Controller Dimensions
3-1          DEC MSCP Subsystem Logical and Physical Configuration
3-2          QD21 Subsystem Logical and Physical Configuration
3-3          Sample SHOW CONFIGURATION
3-4          CONFIGURE Command Listing
4-1          QD21 Configuration Reference Sheet
4-2          Switch Setting Example
4-3          QD21 Disk Controller Assembly
4-4          Drive Cabling
5-1          Fault Isolation Chart
7-1          QD21 Block Diagram
8-1          Control Pin/Signal Assignments at ESDI Disk Drive Interface
             (Connector J1)
8-2          Data Pin/Signal Assignments at ESDI Disk Drive Interface
             (Connector J2 or J5) 
8-3          Status and Control Interface
C-1          Setting the Switches on the Wren III

LIST OF TABLES
--------------
1-1          Basic Contents
1-2          QD21 Options
2-1          QD21 General Specifications
2-2          QD21 Environmental Specifications
2-3          QD21 Physical Specifications
2-4          QD21 Electrical Specifications
3-1          Subsystem Configuration Example
3-2          Device Names
4-1          QD21 Switch Definitions and Factory Configuration
4-2          QD21 Jumper Definitions and Factory Configuration
4-3          Controller Address Switch Settings
4-4          Bootstrap MSCP Device Number
4-5          MSCP Device Number for the First Drive Supported by
             a QD21 at an Alternate Address
4-6          QD21 Internal Cabling Kit (P/N QD2113001)
4-7          Interface and Cable Components
4-8          MicroVAX Offsets
4-9          LSI-11 Offsets
4-10         Configuration Bit Values in Decimal
5-1          Flow Chart Symbol Definitions
5-2          LED Error Codes
5-3          MSCP Fatal Error Codes Used by the QD21
5-4          Fatal Error Codes
6-1          QD21 and SA Registers
8-1          LSI-11 Bus Interface Pin Assignments
8-2          Control and Status Interface Pin Function Description
A-1          SYSGEN Device Table
A-2          Priority Ranking for Floating Vector Addresses
A-3          CSR and Vector Address Example
A-4          Floating CSR Address Assignment Example
C-1          Drive Configuration Parameter Values
C-2          Drive Option Settings
C-3          CDC Wren III Switch Settings

                       ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                       ³ Section 1  INTRODUCTION ³
                       ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

1.1   Overview
--------------
The QD21 Disk Controller, designed and manufactured by Emulex Corporation, is a
Mass Storage Control Protocol (MSCP) compatible controller that interfaces with
Enhanced Small Device Interface (ESDI) disk drives.  This manual is designed to
help you install and use your QD21 Disk Controller.  It assumes that you have 
some knowledge of hardware configuration, LSI-11 architecture and terminology, 
and interpretations of error messages and device register contents.  The 
contents of the eight sections and three appendices are described as follows:

  Section 1  General Description:  This section contains an overview of the 
             QD21 Disk Controller.

  Section 2  Controller Specification:  This section contains the specification
             for the QD21 Disk Controller.

  Section 3  Planning the Installation:  This section contains the information 
             necessary to plan your installation, including MSCP subsystem and
             operating system considerations.

  Section 4  Installation:  This section contains the information needed to set
             up and physically install the controller, including switch 
             settings and cabling.  It also describes the firmware-resident
             diagnostics and contains instructions for loading drive 
             configuration parameters into the NOVRAM.

  Section 5  Troubleshooting:  This section describes fault isolation 
             procedures that can be used to pinpoint trouble spots.

  Section 6  Registers and Programming:  This section describes the QD21's 
             LSI-11 bus registers and presents an overview of the Mass Storage 
             Control Protocol (MSCP).

  Section 7  Functional Description:  This section describes the controller 
             architecture.

  Section 8  Interfaces:  This section describes the controller LSI-11 bus and
             ESDI interfaces.

  Appendix A  Autoconfigure:  This appendix describes the DEC algorithm for the
              assignment of CSR addresses and vector addresses.

  Appendix B  PROM Removal and Replacement:  This appendix contains 
              instructions to remove and replace the firmware so that the user
              can upgrade the QD21 Disk Controller in the field.

  Appendix C  Disk Drive Configuration Parameters:  This appendix contains 
              configuration parameters for supported ESDI disk drives.

1.2   Subsystem Overview
------------------------
The QD21 Disk Controller connects high-capacity mass storage peripherals to the
LSI-11 bus on computers manufactured by Digital Equipment Corporation (DEC).
The QD21 implements DEC's Mass Storage Control Protocol (MSCP) to provide a 
software-transparent interface for the host DEC computer.  To provide 
traditional Emulex flexibility in peripheral selection, the QD21 uses the
industry standard Enhanced Small Device Interface (ESDI) interface as its 
peripheral interface.  The QD21 supports the magnetic disk drive and serial 
options of ESDI.  For more information on the QD21's ESDI interface, see 
subsection 8.1.3.

1.2.1   Mass Storage Control Protocol (MSCP)
--------------------------------------------
MSCP is a software interface designed to lower the host computer's mass storage
overhead by offloading much of the work associated with file management into an
intelligent mass storage subsystem.  In concert with ESDI compatible 
peripherals, the QD21 provides just such a subsystem.  The QD21 relieves the 
host CPU of many file maintenance tasks.  The QD21 Disk Controller performs 
these MSCP functions: error checking and correction, bad block replacement, 
seek optimization, command prioritizing and ordering, and data mapping.

This last feature is, perhaps, the most important. This feature allows the host
computer's operating system software to store data in logical blocks that are
identified by simple logical block numbers (LBNs). Thus, the host does not need
to have detailed knowledge of the peripheral's geometry (cylinders, tracks,
sectors, etc.).  This feature also makes autoconfiguration a simple matter.
During system start-up, the host operating system queries the subsystem to find
its capacity (the number of logical blocks that the subsystem can store).

Because the host operating system does not need to have detailed knowledge of 
its mass storage subsystem, the complexity of the operating system itself has 
been reduced.  This reduction comes about because only one or two software 
modules are required to allow many different subsystems to be connected to a 
host.

1.3   Physical Organization Overview
------------------------------------
The QD21 Disk Controller is a modular, microprocessor-based disk controller 
that connects directly to the host computer's Q-bus backplane.  The 
microprocessor architecture ensures excellent reliability and compactness.

The QD21 is contained on a single dual-wide printed circuit board assembly 
(PCBA) that plugs directly into a Q-bus backplane slot.

The QD21 supports up to two physical or four logical disk drives.  Aggregate 
data storage capacities are limited only by the capacities of the peripherals.
Figure 1-1 shows one possible ESDI configuration.

                             ÚÄÄÄÄÄÄ¿  ESDI (DATA)    ÚÄÄÄÄÄÄÄÄ¿
                             ³      ³<ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>³ ESDI   ³
                             ³      ³ ESDI (CONTROL)  ³ DISK   ³
          ÚÄÄÄÄÄ¿ LSI-11 BUS ³      ³<ÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ>³ DRIVE  ³
          ³ CPU ³<ÍÍÍÍÍÍÍÍÍÍ>³ QD21 ³           ³     ÀÄÄÄÄÄÄÄÄÙ
          ÀÄÄÄÄÄÙ            ³      ³           ³     ÚÄÄÄÄÄÄÄÄ¿
                             ³      ³           ÀÄÄÄÄ>³ ESDI   ³
                             ³      ³                 ³ DISK   ³
                             ³      ³<ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>³ DRIVE  ³
                             ÀÄÄÄÄÄÄÙ  ESDI (DATA)    ÀÄÄÄÄÄÄÄÄÙ

              Figure 1-1.  QD21 Subsystem Configuration
              =========================================

1.4   Subsystem Models
----------------------
The QD21 Disk Controller, with appropriate peripherals, provides a DEC 
MSCP-compatible mass storage subsystem.  The QD21 is pictured in Figure 1-2.
The QD21 is identified by a top level assembly tag that is glued to the 8031
microprocessor chip on the PWB.  The QD21 top level assembly number is given
in Table 1-1 along with the part numbers of the items that are delivered with
the QD21.

                       Table 1-1.  Basic Contents
         ÚÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
         ³ Itm ³ Qty ³      Description        ³  Part Number ³
         ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
         ³  1  ³  1  ³ QD21 Disk Controller    ³ QD2110202-00 ³
         ³  2  ³  1  ³ 22-Bit Addressing Kit   ³ QD0113002-00 ³
         ³  3  ³  1  ³ QD21 Technical Manual   ³ QD2151002-00 ³
         ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

Options are specified as separate line items on a sales order.  An example of 
an actual sales order is shown in Figure 1-3.

        Itm ³ Qty ³ Model Number ³    Comment/Description
        ÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
         1  ³  1  ³ QD21         ³ Disk Controller implementing
            ³     ³              ³ DEC MSCP with ESDI drives
 
                   Figure 1-3.  Sales Order Example
                   ================================

1.5   Features
--------------
The following features enhance the usefulness of the QD21 Disk Controller.

1.5.1   Microprocessor Design
-----------------------------
The QD21 design incorporates an eight-bit, high-performance CMOS microprocessor
to perform all controller functions.  The microprocessor approach provides a 
reduced component count, high reliability, easy maintainability, and the 
microprogramming flexibility that allows MSCP to be implemented without
expensive, dedicated hardware.

1.5.2   Firmware Resident Diagnostics
-------------------------------------
The QD21 disk controller firmware incorporates a self-contained set of disk 
preparation and diagnostic utilities.  These utilities are contained in QD21
Revision E and above firmware.  Controllers with this firmware are easily 
identified by a silver tag labeled with the top assembly number QD2110201-00E.

These utilities allow the user to communicate directly with the QD21 via a 
firmware resident terminal driver that is compatible with either CRT or 
hardcopy devices connected to an LSI-11 or MicroVAX console port.  These
firmware-resident diagnostics (F.R.D.) provide several important disk 
preparation functions, including the ability to:

  o  Configure the controller NOVRAM
  o  Format the drive
  o  Test the disk surface and replace defective blocks, and
  o  Perform reliability testing of the attached disk subsystem.

1.5.3   Custom Configuration Capability
---------------------------------------
An on-board NOVRAM can be programmed for two independent physical drive 
configurations.  Using the firmware-resident utilities, you can control drive
parameters such as gap size, soft or hard sectoring, and the number of sectors
per track.

1.5.4   Automatic Drive Configuration
-------------------------------------
This feature allows you to take advantage of the drive configuration 
information available from the attached ESDI drive to set the drive parameters.
You can configure the QD21 to use this information instead of entering the 
parameters manually.  This feature supports both hard and soft sector formats.  

1.5.5   Self-Test
-----------------
The QD21 incorporates an internal self-test routine which exercises all parts 
of the microprocessor, the on-board memory, the buffer controller, the disk 
formatter chip, and the Host Adapter Controller (HAC).  Although this test does
not completely test all circuitry, successful execution indicates a very high 
probability that the disk controller is operational.  If the QD21 detects an 
error during self-test, it leaves three light-emitting diodes (LEDs) ON and 
sets an error bit in the Status and Address (SA) register (base address plus 2)

1.5.6   Error Control
---------------------
The disk controller presents error-free media to the operating system by 
correcting soft errors and retrying operations without intervention by the host

1.5.7   Host-Initiated Bad Block Replacement
--------------------------------------------
The QD21 uses DEC-compatible host initiated bad block replacement to 
dynamically replace any defective blocks that occur during the life of the 
system.  For maximum reliability, the QD21 reports even corrected single bit
errors as candidates for replacement.

1.5.8   Media Defect List Management
------------------------------------
During format operations, the QD21 replaces all blocks on the disk that are 
labeled bad in the Manufacturer's Defect List.  After formatting, the firmware-
resident utilities can be used to test the entire disk surface with four worst-
case data patterns and replace any pattern-sensitive blocks not found by the 
manufacturer.  QD21 supports both 256- and 512-byte defect list formats.

1.5.9   Seek Optimization
-------------------------
The QD21 is able to pool the various seeks that need to be performed and 
determine the most efficient order in which to do them.  This is an especially
important feature in heavily loaded systems.  The disk controller's ability to 
arrange seeks in the optimum order saves a great deal of time and makes the 
entire system more efficient.

1.5.10   Command Buffer
-----------------------
The QD21 contains a buffer that is able to store 13 MSCP commands.  This large 
buffer allows the subsystem to achieve a higher throughput and to operate at a 
very efficient level.

1.5.11   Adaptive DMA
---------------------
During each DMA data transfer burst, the QD21 monitors the LSI-11 bus for other
pending DMA requests and suspends its own DMA activity to permit other DMA
transfers to occur. The host processor programs the DMA burst length during the
MSCP initialization sequence or the QD21 defaults to 16 words per burst.
Because of these adaptive DMA techniques, the QD21 ensures that CPU functions,
including interrupt servicing, are not locked out for excessive periods of time
by high-speed disk transfers.  The QD21 firmware design includes a DMA burst
delay of either 4 or 8 microseconds to avoid data late conditions (SW2-7).

In addition, the QD21 allows you to modify its DMA operations by disabling the 
adaptive DMA (SW2-8 ON) and defaulting to burst transfers of 8 words or less.

1.5.12   Block-Mode DMA
-----------------------
The QD21 supports block-mode DMA for accessing memory.  In this mode, the 
initial address of the data is transmitted, followed by a burst of up to 16 
words of data.  The memory address is automatically incremented to accommodate
this burst.  Block mode transfers considerably reduce the overhead associated 
with DMA operations.

1.5.13   Twenty-Two-Bit Addressing
----------------------------------
The QD21 supports the 22-bit addressing capability of the extended LSI-11 bus.

1.6   Compatibility
-------------------
This subsection describes the compatibility of operating systems and hardware.

1.6.1   Operating Systems
-------------------------
The QD21 implements MSCP.  Emulex supports its implementation of MSCP beginning
with the indicated version of the following DEC operating systems:

         Operating ³
         System    ³ Version
      ÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ
      Micro/VMS    ³   4.0
      RSTS/E       ³   8.0
      RSX-11M      ³   4.1
      RSX-11M-PLUS ³   2.1
      RT-11        ³   5.1
      Ultrix-11    ³   3.0
      Ultrix-32m   ³   1.1

1.6.2   Hardware Compatibility
------------------------------
The QD21 Disk Controller complies with DEC LSI-11 bus protocol, and it directly
supports 22-bit addressing and block-mode DMA.  The QD21 also supports scatter-
write and gather-read operations on the MicroVAX I.

The QD21 supports the serial mode implementation of the ESDI interface on 
magnetic disk drives that have clocks up to 15 megaHertz.

Emulex has qualified the following disk drives for QD21 support:

  o  CDC Wren III (hard-sectored)
  o  Fujitsu M2246E (soft-sectored)
  o  Hitachi DK512-17 (soft-sectored)
  o  Maxtor EXT-4175 (hard-sectored)
  o  Maxtor EXT-4380 (soft-sectored)
  o  Maxtor XT-4380E (hard-sectored, soft-sectored)
  o  Micropolis 1350 (hard-sectored)
  o  Micropolis 1558 (hard-sectored, soft-sectored)
  o  Siemens 1300 (hard-sectored)

The disk drives supported by the QD21 are not media compatible with comparable 
DEC MSCP products; this is not a problem, however, because of the fixed nature 
of most DEC drives.


                    ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                    ³ Section 2  CONTROLLER SPECIFICATION ³
                    ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

2.1   Overview
--------------
This section contains the general, environmental, physical, electrical, and 
port specifications for the QD21 Disk Controller.

      Subsection  ³        Title
      ÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
          1.2     ³  General Specification
          1.3     ³  Environmental Specification
          1.4     ³  Physical Specification
          1.5     ³  Electrical Specification

2.2   General Specification
---------------------------
Table 2-1 contains a general specification for the QD21 Disk Controller.

                 Table 2-1.  QD21 General Specifications
ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³     Parameter           ³                   Description                   ³
ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³FUNCTION                 ³Providing mass data storage to Digital Equipment ³
³                         ³Corporation (DEC) computers that use the LSI-11  ³
³                         ³                                                 ³
³  Logical CPU Interface  ³Emulates DEC's Mass Storage Control Protocol     ³
³                         ³                                                 ³
³    Diagnostics          ³Embedded diagnostic                              ³
³                         ³                                                 ³
³    Operating System     ³Micro/VMS    V4.0 and above                      ³
³    Compatibility        ³RSTE/S       V8.0 and above                      ³
³                         ³RSX-11M      V4.1 and above                      ³
³                         ³RSX-11M-PLUS V2.1 and above                      ³
³                         ³RT-11        V5.1 and above                      ³
³                         ³Ultrix-11    V3.0 and above                      ³
³                         ³Ultrix-32m   V1.1 and above                      ³
³                         ³                                                 ³
³   CPU I/O Technique     ³Direct Memory Access (DMA), including adaptive   ³
³                         ³techniques and block mode; supports scatter-write³
³                         ³and gather-read operations on the MicroVAX I     ³
³                         ³                                                 ³
³INTERFACE                ³                                                 ³
³                         ³                                                 ³
³  CPU Interface          ³Extended LSI-11 bus interface                    ³
³                         ³                                                 ³
³    Device Base Address  ³                                                 ³
³      Standard           ³17772150                                         ³
³      Alternates         ³17772154                                         ³
³                         ³17760334                                         ³
³                         ³17760340                                         ³
³                         ³17760344                                         ³
³                         ³17760350                                         ³
³                         ³17760354                                         ³
³                         ³17760360                                         ³
³                         ³                                                 ³
³    Vector Address       ³Programmable                                     ³
³                         ³                                                 ³
³    Priority Level       ³BR4                                              ³
³                         ³                                                 ³
³    Bus Loading          ³1 DC Load, 2.5 AC Loads                          ³
³                         ³                                                 ³
³  Peripheral Interface   ³ESDI                                             ³
³                         ³                                                 ³
³    Number of Physical   ³2                                                ³
³    Disk Drives Supported³                                                 ³
³                         ³                                                 ³
³    Drive Sectoring      ³Hard or Soft Sectored                            ³
³                         ³                                                 ³
³    Interface Cables     ³34-line control cable (daisy-chain),             ³
³                         ³maximum 10 ft (3 m)                              ³
³                         ³20-line data cables (radial),                    ³
³                         ³maximum 10 ft (3 m)                              ³
³                         ³                                                 ³
³    Disk Drive Mode      ³Serial                                           ³
³                         ³                                                 ³
³  Firmware Diagnostic    ³                                                 ³
³  Host Console           ³                                                 ³
³                         ³                                                 ³
³    LSI-11               ³DLV11J or Processor-resident console interface   ³
³                         ³                                                 ³
³    MicroVAX             ³Processor-resident console port                  ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

2.3   Environmental Specification
---------------------------------
Table 2-2 contains the environmental specifications for the QD21 Disk 
Controller.

                Table 2-2.  QD21 Environmental Specifications
     ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
     ³    Parameter     ³                Description                   ³
     ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
     ³OPERATING         ³ 10øC (50øF) to 40øC (104øF), where maximum   ³
     ³TEMPERATURE       ³ temperature is reduced 1.8øC per 1000        ³
     ³                  ³ meters (1øF per 1000 feet) altitude          ³
     ³                  ³                                              ³
     ³RELATIVE HUMIDITY ³ 10% to 90% with a maximum wet bulb of 28øC   ³
     ³                  ³ (82øF) and a minimum dewpoint of 2øC (3.6øF) ³
     ³                  ³                                              ³
     ³COOLING           ³ 6 cubic feet per minute                      ³
     ³                  ³                                              ³
     ³HEAT DISSIPATION  ³ 45 BTU per hour                              ³
     ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

2.4   Physical Specification
----------------------------
Table 2-3 contains the physical specifications for the QD21 Disk Controller.

                  Table 2-3.  QD21 Physical Specifications
         ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
         ³     Parameter     ³           Description              ³
         ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
         ³ PACKAGING         ³ Single, dual-wide, four-layer PCBA ³
         ³                   ³                                    ³
         ³   Dimensions      ³ 5.186 by 8.70 inches               ³
         ³                   ³ 13.172  by 22.09 centimeters       ³
         ³                   ³ (see Figure 2-1)                   ³
         ³                   ³                                    ³
         ³   Shipping Weight ³ 3 pounds                           ³
         ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

2.5   Electrical Specification
------------------------------
Table 2-4 lists and describes the electrical specification for the QD21 Disk
Controller.

            Table 2-4.  QD21 Electrical Specification
            ÚÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
            ³ Parameter ³         Description         ³
            ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
            ³  POWER    ³ 5 Vdc + 5%, 2.6 amperes (A) ³
            ÀÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ



                      ÃÄÄÄÄÄÄÄÄ 5.186 inches ÄÄÄÄÄÄ´
                                (13.172 cm)
                      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿          Â
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³    8.700 inches
                      ³                            ³    (22.098 cm)
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      ³                            ³          ³
                      À¿            Ú¿            ÚÙ          ³
                       ÀÄÄÄÄÄÄÄÄÄÄÄÄÙÀÄÄÄÄÄÄÄÄÄÄÄÄÙ           Á

             Figure 2-1.  QD21 Disk Controller Dimensions
             ============================================

                    ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                    ³ Section 3  PLANNING THE INSTALLATION ³
                    ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

3.1   Overview
--------------
This section is designed to help you plan the installation of your QD21 Disk
Controller.  Taking a few minutes and planning the configuration of your
subsystem before beginning its installation should result in a smoother 
installation with less system down time.  This section contains QD21 
application examples and configuration procedures.  The subsections are listed
in the following table:
      Subsection ³      Title
      ÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
        3.2      ³ MSCP Subsystem Configuration
        3.3      ³ A DEC MSCP Subsystem
        3.4      ³ The QD21 MSCP Subsystem
        3.5      ³ Operating Systems, Device and Vector Addresses


3.2   MSCP Subsystem Configuration
----------------------------------
The following paragraphs describe MSCP Subsystem concepts, including 
architecture, unit numbering, capacities, and related concepts.

3.2.1   Architecture
--------------------
MSCP is a protocol designed by DEC for mass storage subsystems using Digital 
Storage Architecture (DSA).  In a MSCP mass storage subsystem, DSA comprises 
three functional and physical layers:

  o  Host Layer.  An MSCP class-driver in the host system receives requests 
     from the operating system and then relays data and commands to the 
     controller in MSCP message packets.

  o  Controller Layer.  The MSCP controller communicates with both the host 
     layer and the mass storage layer.  The controller transmits MSCP message
     packets to and from the host MSCP class-driver and performs data-handling
     functions for the mass storage devices.  The QD21 functions as the
     controller layer.

  o  Mass Storage Layer.  The mass storage peripheral devices communicate with
     the MSCP controller and send or receive data as specified by the MSCP
     controller.

MSCP defines the form of the message packets that are exchanged by the host and
the MSCP controller.  The QD21 implements MSCP in mass storage subsystems 
using ESDI as the peripheral interface.

3.2.2   Peripheral Numbering
----------------------------
Each MSCP peripheral on the system is identified to the operating system by an
MSCP device name.  An MSCP device name consists of a device class identifier 
and a unit number.  The device class is indicated by a two-letter prefix;  MSCP
disk devices are indicated by the prefix DU.

With the exception of MicroVMS systems, DEC operating systems require that all
MSCP peripherals on a system have different MSCP device numbers, even if they 
are managed by separate MSCP controllers at separate LSI-11 bus device 
addresses.  For example, under RSX-11M-PLUS, if there are three peripherals on
the first MSCP controller (at 772150), then the first peripheral on the second
MSCP controller (in floating CSR address space) is numbered DU3.

3.2.3   Peripheral Capacities
-----------------------------
The capacity of peripherals in an MSCP subsystem is measured in logical blocks.
Each logical block contains 512 bytes of data.  The MSCP controller can report
the capacity of a peripheral to the operating system.  For example, a disk 
drive supported by the QD21 is able to store 280731 logical blocks.

3.3   A DEC MSCP Subsystem
--------------------------
Figure 3-1 shows the organization of a typical DEC MSCP subsystem for the 
LSI-11 bus.  The MSCP host and controller functions are combined in a single 
piece of hardware, in this example the DEC RQDX3.  The RQDX3 supports RD51, 
RD52, or RD53 hard disk drives and the RX50 5.25-inch floppy drive.  The RQDX3
plugs directly into the LSI-11 bus and is attached to disk drives via a disk-
drive-native interface.
                                                ÚÄÄÄÄÄÄÄ¿
      ÚÄÄÄÄÄ¿ LSI-11 BUS ÚÄÄÄÄÄÄÄ¿   NATIVE     ³ DRIVE ³
      ³ CPU ³<ÍÍÍÍÍÍÍÍÍÍ>³ RQDX3 ³<ÄÄÄÄÄÄÄÄÂÄÄÄ>³  DU0  ³
      ÀÄÄÄÄÄÙ            ÀÄÄÄÄÄÄÄÙ         ³    ÀÄÄÄÄÄÄÄÙ
                                           ³    ÚÄÄÄÄÄÄÄ¿
                                           ³    ³ DRIVE ³
                                           ÃÄÄÄ>³  DU1  ³
                                           ³    ÀÄÄÄÄÄÄÄÙ
                                           ³    ÚÄÄÄÄÄÄÄ¿
                                           ³    ³ DRIVE ³
                                           ÀÄÄÄ>³  DU2  ³
                                                ÀÄÄÄÄÄÄÄÙ
   Figure 3-1.  DEC MSCP Subsystem Logical and Physical Configuration
   ==================================================================

3.4   The QD21 Subsystem
--------------------------
Figure 3-2 illustrates a typical QD21 MSCP subsystem.  As with the DEC 
implementation, the QD21 is connected directly to the LSI-11 bus. The QD21,
however, uses the ESDI peripheral interface to communicate with one or two 
disk drives.
                             ÚÄÄÄÄÄÄ¿    ESDI (DATA)  ÚÄÄÄÄÄÄÄÄ¿
                             ³      ³<ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>³ ESDI   ³
                             ³      ³  ESDI (CONTROL) ³ DISK   ³
          ÚÄÄÄÄÄ¿ LSI-11 BUS ³      ³<ÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄ>³ DRIVE  ³
          ³     ³            ³      ³           ³     ³ DU0    ³
          ³ CPU ³<ÍÍÍÍÍÍÍÍÍÍ>³ QD21 ³           ³     ÀÄÄÄÄÄÄÄÄÙ
          ³     ³            ³      ³           ³     ÚÄÄÄÄÄÄÄÄ¿
          ÀÄÄÄÄÄÙ            ³      ³           ³     ³ ESDI   ³
                             ³      ³           ÀÄÄÄÄ>³ DISK   ³
                             ³      ³    ESDI (DATA)  ³ DRIVE  ³
                             ³      ³<ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ>³ DU1    ³
                             ÀÄÄÄÄÄÄÙ                 ÀÄÄÄÄÄÄÄÄÙ
       Figure 3-2.  QD21 Subsystem Logical and Physical Configuration
       ================================================================
         
The MSCP subsystem provided by the QD21 is essentially analogous to the DEC 
MSCP subsystem.  As in the DEC subsystem, the QD21 MSCP controller connects
directly to the LSI-11 bus.  As an MSCP controller, the QD21 receives 
requests from the host, optimizes the requests, generates ESDI commands to 
perform the operations, transfers data to and from the host, transfers data 
to and from the device, and buffers data as necessary.  When the command is
complete, the controller sends a response to the host.

The QD21 also performs all of the functions of the peripheral controller,
including serialization and deserialization of data. The QD21 connects to the
peripherals it supports via the ESDI interface.
                                                     
3.4.1   Logical Unit Numbers
----------------------------
As noted in section 3.2.2, most DEC operating systems do not allow any MSCP 
disk devices on one system to have the same unit number, even though they may
be controlled by separate MSCP controllers at different base addresses.

DEC MSCP-type drives can accept unit identification plugs that define addresses
from 0 to 255.  Disk drives controlled by the QD21 do not have this 
flexibility; the QD21 can detect only two unique drive addresses at its 
ESDI interface:  1 and 2.  To prevent a unit-number conflict between the 
QD21's drives and another MSCP controller's drives, the QD21 employs 
switches to change the drive logical unit number that is reported to the 
operating system.
  Example 3-1:  
  An MSCP controller at a standard base address supports four disk drives; a 
  QD21 at an alternate base address supports two disk drives.  An offset of
  4 is specified for the QD21.  This causes the QD21 disk with address 1 
  to be reported to the operating system as logical unit number (LUN) 4.  The
  QD21 disk 2 is reported as LUN 5.

The offset for the logical unit number is specified by using switches SW1-2 
through SW1-4 on the QD21.  See subsection 4.3.3.2.2 for switch setting 
information.

3.4.2   QD21 Subsystem Logical Configuration
----------------------------------------------
This subsection explains the algorithm used by the QD21 to map logical MSCP 
peripherals onto the physical disk drives provided by the QD21 subsystem.

3.4.2.1   Logical Devices
-------------------------
The phrase "logical MSCP disk drive" refers to the disk drive as it appears to
the operating system.  That is, the operating system associates a disk drive of
known type (in this case, an MSCP disk drive) with a unit number and a 
capacity.  The QD21 MSCP controller presents that information to the 
operating system after initialization on command.

Because the MSCP controller is responsible for establishing the relationship 
between unit number and capacity, it is possible for the controller to divide
its physical disk drives into more than one logical unit.  For example, if a 
physical disk drive has a capacity of 584,000 blocks, the MSCP controller can
divide that capacity into two parts of 292,000 blocks each.  (Each part may 
have a different capacity.)  Each part is then assigned a separate unit number,
and the unit number and capacity of each part is presented to the operating 
system. 

The operating system then sees the two parts as separate disk drives, even 
though the data is actually stored on the same physical drive.  The two parts 
are called logical disk drives, and the numbers that identify them are called
MSCP unit numbers.

A drive configuration that supports multiple logical units is specified by the
data that is stored in the configuration Nonvolatile Random Access Memory 
(NOVRAM). Information for programming the configuration NOVRAM is given in 
subsections (4.7, 4.8, and 4.9).  The field that causes a drive to be divided 
into multiple logical units is called the Split Code.  There are four types of
split codes: no split, cylinder split, head split, and reverse head split:

  o  When no split is specified, the entire physical drive is one logical drive

  o  Cylinder split codes divide a physical drive by cylinders.  A Starting 
     Cylinder Offset field in the NOVRAM specifies the first cylinder of the 
     second logical drive.  Alternate cylinders are divided evenly between 
     drives.  For example, a Maxtor 4380, which has 1224 cylinders might be 
     divided so that the first logical unit is assigned cylinders 0 through 
     611 and the second logical unit assigned 612 through 1224.  In this 
     example, the Starting Cylinder Offset has a value of 612.

  o  Head split codes divide the drive by data heads.  A Starting Head Offset
     field in the NOVRAM specifies the first head of the second logical drive.
     When the drive is split by data heads, each logical drive has its own 
     platter(s); consequently, the lower blocks of one logical drive are in the
     same physical cylinder as the lower blocks of the other logical drive. For
     example, a Maxtor 4380 with 15 heads might be divided so that the first 
     logical unit is assigned heads 0 through 7, and the second logical unit is
     assigned heads 8 through 14.  The Starting Head Offset has a value of 8.

  o  Reverse head split codes also divide the drive by data heads, but assign
     the lower numbered heads to drive 1 and the higher numbered heads to drive
     0.  If you entered a reverse split code for the previous Maxtor 4380 
     example, the first logical unit is assigned heads 8 through 14 and the 
     second logical unit is assigned heads 0 through 7.  The Starting Head 
     Offset has a value of 8.

     The head splitting technique has a performance advantage over the cylinder
     method.  Typically, most disk accesses are made in the lower cylinders
     of a disk because many system-oriented files are located there, including
     the drive's directory. Because the low (and high) cylinders are vertically
     aligned between the two logical drives when the head splitting technique
     is used, switching between head-split logical drives requires less head
     movement than switching between cylinder-split drives.

3.4.2.2   Device Numbers
------------------------
The drives supported by the QD21 are assigned MSCP device names by the 
operating system.  As described in subsection 3.2.2, an MSCP device name 
consists of a device class prefix and a device unit number. Drives are assigned
MSCP device numbers beginning with zero (0).  The conventions for numbering 
multiple MSCP drives vary by operating system.

Under RSX-11M, RSX-11M-PLUS and RT-11, DU0 is assigned to the first drive on 
the first MSCP controller, where "first" means the controller located at the 
standard base address.  Unit number 1 would be the second drive on the first 
controller, etc.  If there are two MSCP controllers on the system, the units 
installed on the second begin numbering at n+1, where n equals the highest unit
number of the first MSCP controller.

RSTS/E requires that drives supported by a standard MSCP controller be numbered
starting at 0 and drives supported by an alternate MSCP controller be numbered
starting at 4.

Because MSCP device names under MicroVMS designate the supporting MSCP 
controller, the unit numbering is less restricted.  For example, two drives 
which are supported by a standard MSCP controller might be DUA0 and DUA1 and
a third drive supported by an alternate MSCP controller might be DUB0.

Table 3-1 is an MSCP unit numbering example under the RSX-11M operating system
which shows the MSCP number versus the actual physical addresses assigned to 
all the components.  The physical disk drive (unit number 1) of the second 
controller is split into two logical units.  Note that two device names are 
associated with that drive.

                Table 3-1.  Subsystem Configuration Example
            ÚÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄ¿
            ³            ³                    ³ Drive ³      ³
            ³ QD21       ³                    ³ Unit  ³Device³
            ³ Address    ³ Device Description ³ Number³Name  ³
            ÃÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄ´
            ³ 772150     ³ Micropolis 1350    ³   1   ³ DU0  ³
            ³            ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄ´
            ³            ³ Micropolis 1350    ³   2   ³ DU1  ³
            ÃÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄ´
            ³ 760334     ³ Maxtor 4380        ³   1   ³ DU2  ³
            ³ (Floating) ³ (head split)       ³       ³ DU3  ³
            ³            ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄ´
            ³            ³ Maxtor 4380        ³   2   ³ DU4  ³
            ÀÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÙ
   NOTE  All MSCP peripherals supported by the QD21 use the same device
         identifier - RA81.


                         Section 3 (continued)
                         ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

3.5   Operating Systems, Device and Vector Addresses
----------------------------------------------------
Before the installation of any peripheral device can be considered complete, 
the computer's operating system must be made aware of the new resource.  The 
information provided in this section is intended to supplement your DEC 
operating system resources and to be used as an aid in planning the 
installation of your QD21.

An operating system can be made aware of a new resource in three ways:

  o  The operating system can poll the computer's I/O device address space.

  o  The device can be manually connected using CONNECT or CONFIGURE statements

  o  The user can tell the operating system about a device during an 
     interactive SYSGEN procedure.

The first technique is referred to as autoconfigure, and it is essentially 
automatic.  The second technique requires that CONNECT statements be placed in 
a special command file that is executed each time the computer is bootstrapped.
The third technique, interactive SYSGEN, creates a configuration file that the
operating system references when the system is bootstrapped.  All techniques 
accomplish the same result: they associate a specific device type with a bus 
address and interrupt vector.

Most recent versions of DEC operating systems use autoconfigure to some extent,
and try to follow the same rules.  The RT11 operating system does not use 
autoconfigure, but can locate devices that reside at a standard address.  There
are some differences among operating systems, however, especially with regard 
to MSCP controllers at alternate LSI-11 bus addresses.  The following 
paragraphs address these differences for each supported operating system.  This
discussion includes information on choosing appropriate LSI-11 bus device
addresses and interrupt vectors for the subsystem.

The following operating system discussions give procedures for choosing LSI-11
bus addresses for the first MSCP controller and any subsequent controllers in
the host configuration.  No instructions are provided for programming the 
chosen address into the QD21.  See subsection 4.3.1 for detailed switch 
setting information. 

MSCP-type controllers contain two registers that are visible to the LSI-11 bus
I/O page.  They are the Initialization and Polling (IP) register (base address)
and the Status and Address (SA) register (base address plus 2).  The IP 
register, the CSR address, LSI-11 bus address and the base address all refer to
the same register.  All of the operating systems described in the following 
subsections use the standard LSI-11 bus address of 1772150(8) for the first 
controller on the host system.

Vector addresses for MSCP controllers are not selected by using switches on the
controller, but are programmed into the controller during the Initialization
process.  Many operating systems select the vector address automatically. If an
operating system requires manual input of the vector, the procedure notes that
fact.

Again, although DEC has attempted to standardize treatment of peripherals by 
operating systems, some differences do exist. Table 3-2 lists and describes the
device names assigned to MSCP devices under five operating systems.  Two 
controller names and two drive names are given to indicate the numbering scheme

                        Table 3-2.  Device Names
        ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
        ³ Operating System ³ Controller    ³ Drives Supported    ³
        ³                  ³ First, Second ³ by First Controller ³
        ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
        ³ RSTS/E           ³ RU0, RU1      ³ DU0, DU1            ³
        ³ RSX-11M          ³ ---  ---      ³ DU0, DU1            ³
        ³ RSX-11MPLUS      ³ DUA, DUB      ³ DU0, DU1            ³
        ³ RT-11            ³ Port0, Port1  ³ DU0, DU1            ³
        ³ MicroVMS         ³ PUA, PUB      ³ DUA0, DUA1          ³
        ³ Ultrix-11        ³ uda0, uda1    ³ ra0, ra1            ³
        ³ Ultrix-32m       ³ uda0, uda1    ³ ra0, ra1            ³
        ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

The information regarding operating systems in these subsections is subject to
change.  The following discussions are based on three assumptions:

  o  This is the first pass that is being made through SYSGEN; therefore, no 
     saved answer file exists.  Answer N (no) to questions such as "Use as 
     input saved answer file?"

  o  Your host system configuration conforms to the standard LSI-11 device 
     configuration algorithm (otherwise autoconfigure results are not reliable)

  o  You are generating a mapped version of the operating system on the 
     appropriate hardware (unless you are using RT11).

3.5.1   RSTS/E Operating Systems (V8.0 and above)
-------------------------------------------------
RSTS/E scans the hardware to determine configuration each time the system is 
bootstrapped. The scanning program is called INIT.SYS and it relies on the same
hardware configuration conventions as do the other DEC operating systems.

The RSTS/E operating system can support two MSCP controllers.  The first MSCP 
controller must be located at the standard LSI-11 bus address, 7721508.  
According to DEC documentation, the second unit should be located in floating 
address space.  For an alternate QD21, Emulex suggests specifying a LSI-11 
bus address of 760334(8) using the HARDWARE option of the INIT.SYS program.

The INIT.SYS program uses a user-specified table, located in the currently 
installed monitor, to make exceptions to the autoconfigure algorithm.  This 
table is modified by the HARDWARE option of the INIT.SYS program.  Use of this
table allows an MSCP controller to be placed at virtually any address on the 
I/O page.  Note that this table must be reset any time a new monitor is 
installed.  Emulex suggests using an LSI-11 bus address of 760334(8) for an 
alternate QD21.  An MSCP controller must be located at the standard address 
to be a bootstrap device.

Interrupt vector addresses are assigned to the MSCP controllers by INIT.SYS and
programmed into the devices during initialization.

3.5.1.1   Adding MSCP Support
-----------------------------
Support for an MSCP controller must be included in a monitor at SYSGEN time. To
include support for an MSCP controller in a RSTS/E monitor, respond to the 
SYSGEN question "number of MSCP controllers" with the number of MSCP 
controllers on the system.

Units connected to MSCP controllers will be accessible to an online RSTS/E 
system only after the monitor is successfully SYSGENed and installed with the
INSTALL suboption of the INIT.SYS program, and the units have been successfully
initialized with the DSKINT suboption of INIT.SYS.

3.5.2   Operating Systems (V5.1 and above)
------------------------------------------
The RT-11 Operating System supports up to four MSCP controllers with up to 256
devices (total) on the four controllers.  The following paragraphs discuss the
LSI-11 bus and vector addresses for MSCP controllers under RT-11 in host 
systems with only one MSCP controller and in those with more than one 
controller.  Disk partitioning, a unique feature of RT-11 that is applicable 
regardless of the number of controllers, is also discussed.

3.5.2.1   Installing a Single MSCP Controller
---------------------------------------------
If your host system includes only one MSCP controller, install it with a LSI-11
bus address of 772150(8).  RT-11 will find and install the handler (driver) for
that controller.  In single MSCP controller configurations, it is not necessary
to run SYSGEN.  You may use one of the pregenerated monitors that are provided
with the RT-11 Distribution.  Emulex recommends that you modify the system 
startup command file, STARTx.COM, to properly partition the disk drives.  See
subsection 3.5.2.3.

3.5.2.2   Installing Multiple MSCP Controllers
----------------------------------------------
If your host system includes more than one MSCP controller, you may either 
modify the MSCP handler as described in the RT-11 Software Support Manual or
perform a SYSGEN.  The following procedure describes the SYSGEN technique (user
input is in boldface print):

  1.  Initiate SYSGEN:
      IND SYSGEN<return>

      Answer the next group of questions appropriately.

  2.  Indicate that you want the system to use the startup command file when 
      booting:
      Do you want the startup indirect file (Y)? Y<return>

      The startup command file is required to allow additional MSCP controller
      LSI-11 bus addresses to be specified and to partition the disks 
      consistently when the system is bootstrapped.  Answer the next set of 
      questions appropriately.

  3.  Indicate that you want MSCP support when the Disk Options question 
      appears:
      Enter the device name you want support for [dd]: DU<return>

  4.  Indicate the number of MSCP controllers on your system in response to 
      this question:
      How many ports are to be supported (1)? 2<return>

      RT-11 refers to individual MSCP controllers or controllers as ports. Each
      port has its own LSI-11 bus and vector addresses.

  5.  Specify support for all other devices in your host system configuration 
      as well.  Indicate that there are no more devices by entering a period:
      Enter the device name you want support for [dd]: .<return>

  6.  You must specify the addresses of all MSCP controllers (ports) using the
      SET CSR keyboard command.  To ensure that this is done consistently and
      automatically on power-up, you must add the commands to the system 
      start-up command file, STARTx.COM.  The x stands for the monitor that is
      being used, where x is S, F, or X for single-job, foreground/ background,
      or extended memory, respectively.  Edit the command file to include
      the following statements:
      SET DU CSR=772150          (Default)
      SET DU CSR2=760334         (Floating)
      SET DU VECTOR=154          (Default)
      SET DU VEC2=300

      The LSI-11 bus for the second device can be any unused address in the I/O
      page which is supported by QD21 address switch settings; the vector
      address can be any unused address in the vector page.  Default statements
      are not required.

  7.  Complete SYSGEN according to the DEC documentation.

3.5.2.3   Disk Partitioning
---------------------------
RT-11 is unable to handle drives with a capacity of more than 65,535 blocks 
(33.5M bytes).  To allow drives with larger capacities to be used, RT-11 allows
individual physical drives to be partitioned into multiple logical drives. This
is done by assigning as many logical drive names (DU0, DU1, etc.) to a physical
drive as that drive can support.  The statements that make that assignment
should be placed in the system start-up command file.  This ensures that the 
drives are automatically partitioned every time the system is bootstrapped and
that the partitions are always the same.  Use the following procedure to 
determine the total number of logical drives to be assigned to each physical 
drive.

1.  Determine the drive configuration(s) that you intend to use.  You need to 
    know the LUN of each logical drive and the data storage capacity (in 
    logical blocks) of each logical unit.  If the QD21 is at an alternate 
    LSI-11 bus address (not 772150), then you must specify an MSCP device 
    number by using switches SW1-2 through SW1-4 (see subsection 4.3.3.2.2).

2.  Divide the capacity for each MSCP Unit by 65,535. If the result is a number
    greater than 1, then that MSCP Unit should be partitioned into multiple
    logical units. (The last partition on a disk may be smaller than 65,535 
    blocks.)  Round the result up to the nearest whole number.  That whole 
    number (up to eight) equals the number of logical disks into which
    that MSCP unit should be partitioned.

3.  You must then include a series of statements in the system startup command
    file, STARTx.COM, that assigns logical names to each partition.  Each
    statement has the following format:
    SET DUn UNIT=y PART=x PORT=z

    where n is the logical device name, y is the physical MSCP unit number, x 
    is the partition number, and z is the controller number (specify the
    controller number when two or more controllers are present; do not specify
    the port when only one controller is present).  If you partition any 
    drives, you must do this for each partition on each drive, including drives
    that can hold only one partition.
    Example:   You have selected a Maxtor 4380 that has a capacity of 584,000
               blocks.
    584,000
    ÄÄÄÄÄÄÄ       =   8.91   (9 logical units)
    65,535

    Dividing the unit capacities by 65,535 and rounding the result up to the 
    nearest whole number gives the number of logical units into which each 
    should be partitioned (remember that eight is the maximum).

    You assign logical names to the partitions, beginning with DU0.  For the 
    previous example, the assignments are made as follows:
    SET DU0 UNIT=0 PART=0
    SET DU1 UNIT=0 PART=1
    SET DU2 UNIT=0 PART=2
    SET DU3 UNIT=0 PART=3
    SET DU4 UNIT=0 PART=4
    SET DU5 UNIT=0 PART=5
    SET DU6 UNIT=0 PART=6
    SET DU7 UNIT=0 PART=7

    Because this configuration has only one controller, the port is not 
    defined.  If you had another controller in this configuration, the 
    controllers would be defined as Port 0 and Port 1.

    Modify the system startup command file to include the disk partitioning 
    statements.

3.5.3   RSX-11M Operating Systems (V4.0 and above)
--------------------------------------------------
RSX-11M SYSGEN is an interrogative program that allows a complete, running 
RSX-11M system to be configured for a particular hardware environment.  SYSGEN
is well documented in the RSX-11M System Generation and Installation Guide, and
you are expected to rely primarily on that manual. This explanation is provided
only to remove some ambiguities that the installation of the QD21 may present

SYSGEN supports autoconfigure, and MSCP controllers are detected by 
autoconfigure.  However, autoconfigure detects only the MSCP controller that is
located at the standard LSI-11 bus address.  Additional MSCP controllers at 
alternate addresses must be attached to the operating system manually.

  NOTE  If the QD21 controls the system disk, you must select 22-bit
        addressing (SW2-6 ON) even if your system has only 256K bytes of
        memory.
          
3.5.3.1   Installing a Single MSCP Controller
---------------------------------------------
If you have only one QD21, install it at the standard address (772150) and 
use autoconfigure to connect your peripherals.  The procedure given in the 
RSX-11M System Generation and Configuration Guide is adequate for this purpose.

3.5.3.2   Installing Multiple MSCP Controllers
----------------------------------------------
If you have two MSCP controllers, say a DEC MSCP controller and a QD21, you 
must perform a complete manual initialization.  We recommend that the DEC MSCP
controller be installed at the standard LSI-11 bus address.  Locating the 
QD21 at the alternate LSI-11 bus address does not prevent its being used as
the system device.  Both MSCP controllers are connected to the operating system
by using the following procedure.

1.  Invoke SYSGEN.
    > SET /UIC=[200,200]<return>
    > @SYSGEN<return>

2.  To indicate that you want to use autoconfigure, answer Y (yes) to the 
    following question:
    *  Autoconfigure the host system hardware? [Y/N]: Y<return>

3.  To indicate that you do not want to override autoconfigure results, answer
    N (no) to this question:
    *  Do you want to override Autoconfigure results? [Y/N]: N<return>

    Answer the rest of the questions in the SETUP section appropriately, and 
    continue to the next section, TARGET CONFIGURATION.  In TARGET 
    CONFIGURATION, the defaults presented for the first group of questions 
    should be accurate for your system because autoconfigure was requested.

4.  In response to the question regarding devices, indicate that you have two
    MSCP-TYPE controllers:
    *  Devices: DU=2<return>
       Devices: .<return>

    This entry supersedes the value of 1 that autoconfigure has determined.
    Typing a period (.) terminates device input.

    Continue through the next four sections, HOST CONFIGURATION, EXECUTIVE 
    OPTIONS, TERMINAL DRIVER OPTIONS, and SYSTEM OPTIONS, answering questions
    appropriately.

5.  When you reach the PERIPHERAL OPTIONS section, SYSGEN asks you questions 
    that pertain only to the MSCP devices on your system. (Unless you indicated
    that you wished to override other autoconfigure results when you responded
    to the Devices question, SYSGEN asks questions on those devices.)

    The first question requests information about the controller's interrupt 
    vector address, LSI-11 bus address, the number of DU-TYPE disk drives 
    (there is no default value for this parameter), the number of command 
    rings, and the number of response rings.  The question is asked twice, once
    for controller 0 and once for controller 1, because we have specified
    two DU-TYPE controllers.  The dialog uses the abbreviation contr to 
    indicate controller.
    *  DU contr 0 [D:154,172150,,4,4] 154,172150,3,4,4<return>

    The standard vector address for MSCP controllers is 154.  The vector for a
    second unit should be allocated from floating vector address space.  Any
    unused vector between 300 and 774 can be allocated.  See Appendix A for a
    description of DEC's algorithm for assigning floating vectors.

    The standard LSI-11 bus address for MSCP controllers is 772150.  Emulex 
    recommends that the second unit be located in floating LSI-11 bus address
    space.  See Appendix A for a description of the DEC algorithm for assigning
    floating addresses.

    The number of DU-TYPE disk drives depends on the configuration that you 
    have selected for the QD21, or on the number of drives that are attached
    to a DEC MSCP controller.

    When you select a configuration for the QD21, you are taking into account
    the number of physical disk drives that you are attaching to the QD21's 
    ESDI interface.  When you select a configuration, you are also specifying
    a logical arrangement for the QD21 MSCP subsystem.  Some configurations 
    split one physical drive into two logical drives to make file management 
    easier.  You determine the configuration of each ESDI disk drive when you
    program the QD21's NOVRAM; see subsections 4.7, 4.8, and 4.9.

    The following types of disk drives can be attached to DEC MSCP controllers:
         o  RX50          o  RD51          o  RD52          o  RD53 
         o  RC25          o  RA60          o  RA80          o  RA81

    The RX50 drive contains two 5.25-inch floppy diskettes; count an RX50 as
    two drives. The RC25 has both fixed and removable hard media; count an RC25
    as two drives.

    RSX-11M supports up to eight command and eight response rings; the number 
    of command and response rings that you specify depends on your application.
    Four command and four response rings are reasonable and adequate for most 
    applications.

6.  SYSGEN then asks you to specify the type of disk drive(s) on each 
    controller:
    * DU contr 0 unit 0. is an RA60/80/81/RC25/RD51/RX50 
      [D:RA81]RD51 <return>

    For the DEC MSCP controller, indicate the appropriate peripherals.

    For the QD21, indicate that you have one RA81 for each logical disk drive

    RSX-11M does not tolerate gaps in sequence; the unit numbers must be 
    contiguous.  In addition, the unit numbers specified for each controller 
    must be the same as those reported by the controller during initialization.

7.  Complete the SYSGEN procedure according to DEC documentation.


3.5.4   RSX-11M-PLUS Operating Systems (V2.1 and above)
-------------------------------------------------------
RSX-11M-PLUS SYSGEN is an interrogative program that allows a complete, running
RSX-11M-PLUS system to be configured for a particular hardware environment.
Sysgen is well documented in the RSX-11M-PLUS System Generation and 
Installation Guide, and you are expected to rely primarily on that manual. This
explanation is provided only to remove some ambiguities that the installation 
of the QD21 may involve.

SYSGEN supports autoconfigure, and MSCP controllers are detected by 
autoconfigure.  However, autoconfigure detects only the MSCP controller that is
located at the standard LSI-11 bus address.  Additional MSCP controllers at 
alternate addresses must be attached to the operating system manually.

3.5.4.1   Installing a Single MSCP Controller
---------------------------------------------
If you have only one QD21, install it at the standard address (772150) and 
use autoconfigure to connect your peripherals.  The procedure given in the 
RSX-11M-PLUS System Generation and Configuration Guide is adequate for this 
purpose.

3.5.4.2   Installing Multiple MSCP Controllers
----------------------------------------------
If your initial system configuration includes two MSCP controllers, connect the
alternate MSCP controller to the operating system during the initial SYSGEN. 
We recommend that you use autoconfigure to connect the first controller at the 
standard address (772150).  We recommend that the DEC MSCP controller be 
installed at the standard LSI-11 bus address; locating the QD21 at the 
alternate LSI-11 bus address does not prevent its being used as the system 
device.

If you are adding the second MSCP controller to the system configuration, use 
the Add a Device option of SYSGEN or a complete SYSGEN. The following procedure
describes the Add a Device process (user input is in boldface print):

1.  Invoke SYSGEN.
     > SET /UIC=[200,200]<return>
     > @SYSGEN<return>

2.  To indicate that you want to do a subset of the SYSGEN procedure, answer 
    N (no) to the following questions:
    * Do you want to do a complete SYSGEN?  [Y/N D:Y]: N<return>
    * Do you want to continue a previous SYSGEN from some point? 
    [Y/N D:Y]: N<return>

3.  To indicate that you want to execute a specific module of the SYSGEN 
    procedure, answer Y (yes) to this question:
    * Do you want to do any individual sections of SYSGEN? [Y/N D:Y]: Y<return>

4.  Select the Add a Device section of SYSGEN:
    * Which sections would you like to do?  [S R:0.15.]: H<return>

    Type the letter H to select the Add a Device section.  SYSGEN now asks you
    all of the questions in the Choosing Peripheral Configuration section.

    The questions that SYSGEN asks pertain to the type and number of 
    controllers that are installed on your system.  There is one question for 
    each type of controller that RSX-11M-PLUS can support.  Answer 0 (zero) for
    all types of controllers until you are prompted for the number of UDA-TYPE 
    devices.

5.  When you are asked to specify the number of MSCP-type devices, answer 
    appropriately:
    * How many MSCP disk controllers do you have?[D R:0.63. D:0.] 2<return>

6.  Give the total number of MSCP disk drives (on all controllers) installed on
    the system.
    * How many MSCP disk drives do you have? [D R:0.n. D:1.] 5<return>

    The answer to this question depends on the configuration that you have 
    selected for the QD21 and on the number of drives that are attached to 
    any DEC MSCP controllers.

    When you select a configuration for the QD21, you are taking into account
    the number of physical disk drives that you are attaching to the QD21's 
    ESDI interface.  When you select a configuration, you are also specifying
    a logical arrangement for the QD21 MSCP subsystem.  Some configurations 
    split one physical drive into two logical drives to make file management
    easier.  You determine the configuration of each ESDI disk drive when you
    program the QD21's NOVRAM (see subsections 4.7, 4.8, and 4.9).

    The following types of disk drives can be attached to DEC MSCP controllers:
         o  RX50          o  RD51          o  RD52          o  RD53 
         o  RC25          o  RA60          o  RA80          o  RA81

    The RX50 drive contains two 5.25-inch floppy diskettes; count an RX50 as 
    two drives.  The RC25 drive has both fixed and removable hard media; count
    an RC25 as two drives.

7.  SYSGEN then asks you to specify controllers per disk drives.
    * To which DU controller is DU0: connected? [S R:11]: A<return>

    This question is asked as many times as the number of MSCP drives that you 
    have indicated are on the system.  RSX-11M-PLUS does not tolerate gaps in
    sequence; the MSCP unit numbers must be contiguous. In addition, the unit
    numbers specified for each controller must be the same as those reported by
    the controller during initialization.  Use A for the primary controller and
    B for the alternate controller.

8.  Enter the vector address for each MSCP controller:
    * Enter the vector address of DUA [O R:60774 D:154]

    The standard vector address for MSCP controllers is 154.  The vector for a 
    second unit should be allocated from floating vector address space.  Any
    unused vector between 300 and 774 can be allocated.  See Appendix A for a 
    description of DEC's algorithm for assigning floating vectors.

9.  Enter the CSR address for each MSCP controller:
    * What is its CSR address? [O R:160000177700 D:172150]

    The standard CSR address for MSCP controllers is 772150.  Emulex recommends
    that the second unit be located in floating CSR address space. See Appendix
    A for a description of the DEC algorithm for assigning floating addresses.

10. Specify the number of command rings for each MSCP controller:
    * Enter the number of command rings for DUA [D R:1.8. D:4.] 4<return>

    RSX-11M-PLUS supports up to eight command rings.  The value you specify
    depends on your application. Four command rings are reasonable and adequate
    for most applications.

11. Specify the number of response rings for each MSCP controller:
    * Enter the number of response rings for DUA [D R:1.8. D:4.] 4<return>

    RSX-11M-PLUS supports up to eight response rings. The value you specify 
    depends on your application.  Four response rings are reasonable and 
    adequate for most applications.

3.5.5   MicroVMS Operating Systems
----------------------------------
MicroVAX/MicroVMS supports MSCP controllers at the standard address, 772150, 
and in floating address space.  MicroVMS has a software utility called SYSGEN
which can be used to determine the LSI-11 bus address and interrupt vector 
address for any I/O devices to be installed on the computer's LSI-11 bus.  A 
running MicroVAX/MicroVMS computer system is required in order to use this 
utility.

If you do not have access to a running system, you must determine the LSI-11 
bus addresses and vector addresses manually (although autoconfigure can still 
be used to connect the devices to the computer automatically on powerup).  See 
Appendix A for a description of the algorithm used by SYSGEN to determine 
LSI-11 bus addresses.

The following procedure tells how to use MicroVMS SYSGEN to determine LSI-11 
bus addresses and interrupt vectors.

1.  Log in to the system manager's account.  Run the SYSGEN utility:
    $ RUN SYS$SYSTEM:SYSGEN<return>
    SYSGEN>

    The SYSGEN> prompt indicates that the utility is ready to accept commands.

2.  Obtain a list of devices already installed on the MicroVAX LSI-11 bus by 
    typing:
    SYSGEN> SHOW/CONFIGURATION<return>

     Name: PUA  Units: 1  Nexus: 0  CSR: 772150   Vector1: 154  Vector2: 000
     Name: TTA  Units: 1  Nexus: 0  CSR: 760100*  Vector1: 300* Vector2: 304*
     Name: TXA  Units: 1  Nexus: 0  CSR: 760500*  Vector1: 310* Vector2: 000
     *Floating address or vector
     Note: All addresses and vectors are expressed in octal notation.
     
                 Figure 3-3.  Sample SHOW CONFIGURATION
                 ======================================
     
    SYSGEN lists by logical name the devices already installed on the LSI-11 
    bus.  Make a note of these other devices with floating addresses (greater 
    than 760000) or floating vectors (greater than 300) that you plan to 
    reinstall with your QD21.

3.  To determine the LSI-11 bus addresses and vectors that autoconfigure 
    expects for a particular device type, execute the CONFIGURE command:
    SYSGEN> CONFIGURE<return>
    DEVICE>

    Specify the LSI-11 bus devices to be installed by typing their LSI-11 bus 
    names at the DEVICE prompt (the device name for MSCP controllers under 
    MicroVMS is UDA).
    DEVICE> UDA,2<return>
    DEVICE> DHV11<return>
    DEVICE> DZ11<return>

    A comma separates the device name from the number of devices of that type 
    to be installed.  The number of devices is specified in decimal.

    In addition to the QD21, you need only specify devices that have floating
    addresses or vectors. Devices with fixed addresses or vectors do not affect
    the address or vector assignments of devices with floating addresses and 
    vectors.

4.  Indicate that all devices have been entered by pressing the <ctrl> and Z 
    keys simultaneously:
    DEVICE> ^Z

    SYSGEN lists the addresses and vectors of the devices entered in the format
    shown in Figure 3-4.
    SYSGEN>  CONFIGURE
    DEVICE> DZ11
    DEVICE> DHV11
    DEVICE> UDA,2
    DEVICE> ^Z
    Device: UDA     Name: PUA    CSR: 772150    Vector: 154    Support: yes
    Device: DZ11    Name: TTA    CSR: 760100*   Vector: 300*   Support: yes
    Device: UDA     Name: PUB    CSR: 760354*   Vector: 310    Support: yes
    Device: DHV11   Name: TXA    CSR: 760500*   Vector: 320    Support: yes
    *Floating address or vector
    Note: All addresses and vectors are expressed in octal notation.

                 Figure 3-4.  CONFIGURE Command Listing
                 ======================================

5.  Note the CSR addresses listed for the LSI-11 bus devices in floating 
    address space.  Program the listed addresses into non-Emulex devices as
    instructed by the manufacturer's documentation. For the QD21, program the
    address given for the QD21 (lowest numerical address) into the board as
    described in subsection 4.3.1.

6.  Complete SYSGEN according to the DEC documentation.

    If you want to select a nonstandard address for the QD21, that is one 
    that differs from the address selected by the CONFIGURE command, you must 
    enter CONNECT statements in the SYCONFIG.COM file that is in the system 
    manager's account, SYS$MANAGER.  Use the syntax of the CONNECT statements 
    as described in the DEC documentation on MicroVMS SYSGEN.

    NOTE  Do not alter the STARTUP.COM or UVSTARTUP.COM command files in the
          main system account, SYS$SYSTEM.
          
3.5.6   Ultrix-11 Operating Systems (V3.0 and above)
----------------------------------------------------
The Ultrix-11 Version 3.0 system supports up to a total of four MSCP disk 
controllers, but only one of each type of controller. Therefore, to add support
for two MSCP controllers, the system generation procedure must be told that 
there is, for example, one UDA50 controller and one RQDX1 controller.  The 
choices are:
        Controller name          device name    disk name
        UDA50                         ra           ra??
        KLESI                         rc           rc??
        RQDX1, RQDX2, or RQDX3        rq           rd??
        RUX1                          rx           rx??

    NOTE  A bug exists in version 3.0 that prevents actually using more than
          three controllers.  When an RQDX1, RQDX2, or RQDX3 is specified, the
          sysgen program will not allow specifying an RUX1 controller, and
          vice versa. 

3.5.6.1   Sysgen
----------------
To add a device to an Ultrix-11 kernel, the sysgen program must be run to 
create and make a new kernel. Creating a kernel involves the creation of a
configuration file and then "making" the kernel from this configuration file.

A dialogue mode is used to enter various system parameters.  The question:

Disk controller type: 
<rh11 rh70 rp11 rk611 rk711 rl11 rx211 rk11 
uda50 kda50 rqdx1 rqdx2 rqdx3 klesi rux1> ?

asks for the specification of a disk controller.  You must choose a different 
controller type for each MSCP controller on your system, even if they are all 
QD21s.

NOTE  The order in which you enter each controller is very important.  The
      order becomes the controller number. The same order must also be used
      when creating the special files (see below). 

For each MSCP controller specified, one of the following statements will be 
typed: 
   First MSCP controller type:
   Second MSCP controller type:
   Third MSCP controller type: 

and, depending on the controller name specified previously, the next question 
will differ.  See the appropriate correlation below:
   Disk Controller Type        Next Sysgen Question
   uda50 or kda50              Drive 0 type <ra60 ra80 ra81> ?
   klesi                       Drive 0 type <rc25> ?
   rqdx1/2/3 or rux1           Drive 0 type <rx50 rd51 rd52 rd53> ?
 
Note that it doesn't matter which drive type you choose.  Just enter one of the
supplied names for each drive you have connected to each controller.

The next two questions refer to the controller's CSR and vector addresses:
   CSR address <172150> ?
   Vector address <154> ?

   The defaults for the CSR and Vector address will always be 172150 and 154, 
   respectively.  Be sure to enter the correct CSR value.  Since the MSCP
   controller accepts a software-defined vector, an unused vector from the 
   floating address space should be used for all nonstandard address 
   controllers.  Emulex suggests that you use a decrementing (by 4) vector 
   address starting at 700 (octal).  This will prevent you from using a vector 
   address that is already in use.

3.5.6.2   Special Files
-----------------------
The Ultrix operating system communicates with devices on the system by the use 
of special files.  These files contain pointers into a system table that lists
the entry points for a corresponding driver for that device.  There must be a
special file for each device (and each partition for disks) on the system in
order for Ultrix to communicate with that device.  Some devices will have two
special files associated with a device: one for use with character mode, and
the other for block mode. These special files exist in the account "/dev".

The special files for Ultrix-11 are created with the 'msf' program (make 
special file). If no options are supplied, this program enters a dialogue mode:

# /etc/msf 

The "msf" program will issue the prompt:

Command <create exit help remove table>:

Use the "c" command to create the special files.

Device name (? for help) <rp06,dz11,lp11,etc>:

The "msf" program does not understand the notations for different controller
types.  Instead, it uses the device name and controller number in order to
create the special files.  For example, the special files for ra60, ra80, and
ra81 would be "ra", the special file for an rc25 would be "rc", and the special
files for an rd51/2/3 would be "rd".  Therefore, you must enter a unique device
name for each controller.  It is suggested that you use the same device names
used previously with the sysgen program.

The next two questions are:

MSCP controller number <0 1 2 3>:
Unit number <0 -> 7 or all>:

The MSCP controller number assigned to each controller is determined by the
order in which you entered the devices to the sysgen program; that is, the
number for the first controller is 0.  

The unit number for each drive (as it is identified by SW1-2 through SW1-4)
must match the drive's specification in the configuration file.  In addition,
the drive to be booted from must be 0, regardless of whether the controller is
at the standard or an alternate address.

For ra, rc, and rd type devices, the next question will be asked:

Assume standard disk partitions (? for help) <y or n> ?

If you answer "no", the next question will be asked: 

Create partitions <0 -> 7 or all>?

You should always answer "all". 

3.5.6.3   Newfs
---------------
The "newfs" program is used to create file systems on specified partitions. The
newfs program requires no arguments and immediately enters a dialogue mode. See
the Ultrix-11 System Manager's Guide for more information on newfs.

3.5.6.4   Volcopy
-----------------
Once a device is configured into your current kernel, you can copy an existing
file system onto a new partition with the 'volcopy' program.  The new partition
will be created with the identical size parameters of the original file system.
See the Ultrix-11 System Manager's Guide for more information on volcopy.

3.5.6.5   Copying a Bootstrap
-----------------------------
A new bootstrap can be copied onto a new system disk with the "dd" program. The
command:
# dd if=/mdec/rauboot of=/dev/ra00 
will copy the bootstrap file onto block zero of ra0.

NOTE  V7M-11 V1.0 and Ultrix-11 V2.0 did not support self-sizing disks and
      are, therefore, unusable with the Emulex MSCP controllers. 

3.5.7   Ultrix-32 Operating Systems
-----------------------------------
The Emulex MSCP class disk disk subsystems emulate the DEC DSA UDA-50/KDA-50/
RA81 (MSCP) disk subsystem.  They report that they are of controller type "DU"
and of device type "RA81". However, when asked for the number of logical blocks
they do not return a size value that matches that of a "real" DEC RA81.

3.5.7.1   The Kernel
--------------------
Support for MSCP controllers must be included in a monitor when rebuilding the
kernel.  The configuration file is edited to reflect the number of controllers
and the number of drives connected to each controller.  The Ultrix-32 system
supports two MSCP disk controllers. 

Ultrix-32 does not require that the units be in sequential order.  However, the
MSCP device number for the drive to be booted from MUST be 0 regardless of the
controller's LSI-11 bus address.  Further, be certain that the MSCP device 
number of each drive (as it is identified by SW1-2 through SW1-4) matches the
drive's specification in the configuration file.  

The following example shows two controllers, the first with two drives, the
second with one:

controller  uda0  at uba0 csr 0172150  vector udintr
disk        ra0   at uda0 drive 0
disk        ra1   at uda0 drive 1
controller  uda1  at uba0 csr 0160334  vector udintr
disk        ra2   at uda1 drive 2

In this example, the first unit on the second controller must be MSCP device 
number two regardless of the units on the first controller. 

3.5.7.2   Special Files
-----------------------
The Ultrix operating system communicates with devices on the system by the use
of special files.  These files contain pointers into a system table that lists
the entry points for a corresponding driver for that device.  There must be a
special file for each device (and each partition for disks) on the system in
order for Ultrix to communicate with that device.  Some devices will have two
special files associated with a device: one for use with character mode, and
the other for block mode.  These special files exist in the account "/dev".

There is a shell script, called "MAKEDEV" (uppercase important), on the Ultrix-
32 system to help build these special files.  The format of this command is:

% /dev/MAKEDEV device ...

This script passes your input to the program "mknod" to create the special
files.  You should use this command file to create the special files for each
disk you wish to connect to the system.  An example for two disks is:

% /dev/MAKEDEV ra4 ra5

This example assumes that you have already added the device into the 
configuration file, and you chose the logical names ra4 and ra5 for your disks.

3.5.7.3   Autoconfigure
-----------------------
At boot time, Ultrix-32 attempts to auto-configure the devices included in the
booted monitors configuration file.  If the device was not included in the
configuration files, it will not be configured into the running system.  If the
device is not present, Ultrix will skip it.

When Ultrix finds a device at autoconfigure time it prints a message as follows

rqd0 at csr 172150 vec 774, ipl 17
ra0 at rqd0 slave 0
ra1 at rqd0 slave 0
rqd1 at csr 160334 vec 770, ipl 17
ra2 at rqd1 slave 0

The CSR address were set in the configuration file.  The vectors are assigned
sequentially in reverse order by the operating system.  If the CSR or unit 
numbers don't match the configuration file, the device will be skipped (and no
message will be printed).

3.5.7.4   Disk Partitions
-------------------------
Ultrix allows a user to logically subdivide a disk into sections called 
"partitions".  Disk partitions were created because the first Unix operating
systems could access only a limited amount of space on large disks.  Disk 
partitioning lets several Unix file systems reside on the same disk, one file
system per partition.  This allows the operating system to utilize the entire
disk.

Each disk has a partition table that defines the starting location and size
(both in blocks) of each partition on that disk.  When a disk is opened by the
operating system (for the very first time), it writes the partition size table
into the super block of partition "a" (the first partition) on the disk.

3.5.7.5   Disk Partition Modifications
--------------------------------------
Modifications to a disk's partition table is done with the "chpt" command each
time a disk is initialized or reinitialized. The "chpt" command allows a system
manager to alter a particular partition's location and size characteristic.

The operating system initializes the disk's partition table with that of a real
DEC RA81's size table (found in the disk driver) on its first opening.  The
system manager should then edit these sizes (with "chpt" command) to match the
system needs.

3.5.7.6   Default Partition Modifications
-----------------------------------------
It is also possible to modify the default RA81 partition size table, which is
stored in the device driver; this would eliminate the need for editing the
partition table each time the disk is initialized.

When DEC reorganized the Berkeley 4.2 Unix system to create Ultrix-32, they set
it up to allow the distribution of the operating system in a binary format.
This allowed them to distribute a minimum amount of source code to binary
license holders.  They separated each of the drivers and system kernel modules
into two sections:  a code portion and a data portion.  The code portion does
not require recompilation depending on the selected options at SYSGEN time;
this is supplied in object format (xx.o).  The data portion requires selection
parameters based on sysgen answers; this is supplied in source code format 
(xx_data.c).  Making changes to this table will alter the default partition
size characteristics for new disks. An example of the changes to the uda driver
is included here.

Example:

/usr/sys/data/uda_data.c:

}, ra81_sizes[8] ={
    15884,  0,         /* A=blk 0 thru 15883 */
    66880,  15884,     /* B=blk 15884 thru 82763 */
    -1,     0,         /* C=blk 0 thru end */
    0,      0,         /* D= not used */
    0,      0,         /* E= not used */
    0,      0,         /* F= not used */
    -1,     82764,     /* G=blk 82764 thru end */
    0,      0,         /* H= not used */
};

The -1 above indicates the end of the disk.

3.5.7.7   Newfs
---------------
The newfs program speeds up the creating of a file system on a partition.  It
looks up information, in the file /etc/disktab, on the disk specified by the
system manager and creates the file system according to those default values.
An example of the changes to the /etc/disktab file have been included here.

Example:

/etc/disktab:

qd21|QD21|Emulex QD21 Fujitsu Eagle M2351A Winchester:\
      :ty=winchester:ns#47:nt#20:nc#840:\
      :pa#15884:ba#4096:fa#512:\
      :pb#66880:bb#4096:fb#512:\
      :pc#789600:bc#4096:fc#1024:\
      :pg#706836:bg#4096:fg#1024:

3.5.7.8   Suggestions/Warnings
------------------------------
There is a maximum of eight partitions per disk.  The partitions form logical
boundaries on the disk, separating each file system from all others.  These
logical divisions are useful for disk management because you can put similar
types of users, files, directories or projects all on the same file system.
Because a file system can never exceed its partition in size, you can use
partitions to regulate disk use.

There are certain areas of the disk which, by default, are reserved for the
operating system. By mounting the swap space, for example, on its own partition
important data can not be overwritten when data from memory is swapped to the 
disk.  The Ultrix-32 systems use partition "b" for the swap file.  If you plan
to use your own partition values, be sure to allocate an area on your system
disk for a swap file.

For more information on disk partitioning and modifications to the partition
sizes, see Appendix C, "Disk Partitioning", in the Ultrix-32 System Manager's
Guide.

The program "diskpart" is used to create entries for the disk driver or for the
"disktab" file.  It creates a template based on the default rules used at
Berkeley.  The following is a table defining the Berkeley defaults:

    Partition  20-60 MB  61-205MB    206-355 MB  356+ MB
    a          15884     15884       15884     15884
    b          10032     33440       33440     66880
    c *        all       all         all       all
    d          15884     15884       15884     15884
    e          unused    55936       55936     307200
    f *        unused    end         end       end
    g *        end       end         end       end

    * The 'c' partition is, by convention, used to access the entire disk.  
      In normal operation, either the 'g' partition is used, or the 'd', 'e',
      and 'f' partitions are used.  The 'f' and 'g' partitions are variable
      sized, occupying whatever space remains after allocation of the fixed
      sized partitions.

NOTE  Ultrix-32 V1.0 did not support self-sizing disks and is, therefore,
      unusable with the Emulex MSCP controllers.  The "diskpart" program
      was not included on the Ultrix-32 V1.1 distribution kit.

                       ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                       ³ Section 4  INSTALLATION ³
                       ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

4.1   Overview
--------------
The procedure for installing the QD21 Disk Controller is described in this
section.  The subsection titles are listed below to serve as an outline of the
procedure.

    Subsection³     Title
    ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
        4.2   ³ Inspection
        4.3   ³ Disk Controller Setup
        4.4   ³ Physical Installation
        4.5   ³ ESDI Drive Preparation
        4.6   ³ Cabling
        4.7   ³ NOVRAM Loading, Disk Formatting, and Testing
        4.8   ³ F.R.D. Options
        4.9   ³ Drive Configuration Parameters
        4.10  ³ Operation

If you are unfamiliar with the subsystem installation procedure, Emulex
recommends reading this Installation Section before beginning.

4.1.1   Subsystem Configurations
--------------------------------
This section is limited to switch setting data and physical installation
instructions.  No attempt is made to describe the many subsystem configurations
that are possible.  If you are not familiar with the possible configurations,
we strongly recommend reading Section 3, PREPARING THE INSTALLATION, before
attempting to install this subsystem.

When you are installing the subsystem, you should make a record of the
subsystem configuration and environment.  Figure 4-1 is a Configuration Record
Sheet that lists the information required and shows where the data can be found
This information will be of help to an Emulex service representative should
your subsystem require service.

4.1.2   DIP Switch Type
-----------------------
Switch-setting tables in this manual use the numeral one (1) to indicate the ON
(closed) position and the numeral zero (0) to indicate the OFF (open) position.

The two DIP switch types used in this product are shown in Figure 4-2.  Each is
set to the code shown in the switch setting example.

4.1.3   Maintaining FCC Class A Compliance
------------------------------------------
Emulex has tested the QD21 Intelligent Disk Controller with DEC computers
that comply with FCC Class A limits for radiated and conducted interference.
When properly installed, the QD21 does not cause compliant computers to 
exceed Class A limits.

There are two possible configurations in which the QD21 and its associated
ESDI peripherals can be installed:

  o  With both the QD21 Disk Controller and the ESDI disk drives both 
     mounted in the same cabinet, and 

  o  With the QD21 mounted in the CPU cabinet and the ESDI drives mounted
     in a separate cabinet.

To limit radiated interference, DEC completely encloses the components of its
computers that generate or could conduct radio-frequency interference (RFI) 
with a grounded metal shield (earth ground). During installation of the QD21,
nothing must be done that would reduce this shield's effectiveness.  That is,
when the QD21 installation is complete, no gap in the shield that would allow
RFI to escape can be allowed.

Conducted interference is generally prevented by installing a filter in the ac
line between the computer and the ac outlet.  Most power distribution panels
that are of current manufacture contain suitable filters.

The steps that must be taken to maintain the integrity of the shield and to 
limit conducted interference are explained fully in subsection 4.6.

4.2   Inspection
----------------
Emulex products are shipped in special containers designed to provide full
protection under normal transit conditions.  Immediately upon receipt, the
shipping container should be inspected for evidence of possible damage incurred
in transit.  Any obvious damage to the container, or indications of actual or
probable equipment damage, should be reported to the carrier company in
accordance with instructions on the form included in the container.

Unpack the QD21 subsystem and, using the shipping invoice, verify that all
equipment is present.  Verify also that model or part numbers (P/N), revision
levels, and serial numbers agree with those on the shipping invoice. Subsection
1.4 explains model numbers and details kit contents.  These verifications are
important to confirm warranty.  If evidence of physical damage or identity
mismatch is found, notify an Emulex representative immediately.  If the
equipment must be returned to Emulex, it should be shipped in the original
container.

Visually inspect the QD21 Disk Controller after unpacking.  Check for such
items as bent or broken connector pins, damaged components, or any other
evidence of physical damage.

Examine all socketed components carefully to ensure that they are properly
seated.

4.3   Disk Controller Setup
---------------------------
Several configuration setups must be made on the QD21 Disk Controller before
inserting it into the chassis. These setups are made by option switches SW1 and
SW2.

Figure 4-3 shows the locations of the configuration switches referenced in the
following paragraphs.
                                     LED1
                                     :LED2
                                     ::LED3
                  ÚÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÂÂÂÂÄÄÄÄÂÄ¿
                  ³ ÀÄÄÄÄÄÄÄÁÄÄÄÄÄÄÙ    ÀÄÄÄÄÙ ³ 
                  ³     J1        J2      SW1  ³ 
                  ³ÚÄÄÄÄÄÄÄÄÄ¿           ÚÄÄÄÄ¿³ 
                  ³ÀÄÄÄÄÄÄÄÄÄÙ           ÀÄÄÄÄÙ³ 
                  ³  J3                   J5   ³ 
                  ³ÚÄÄÄÄÄÄ¿EFG           Ú¿U29 ³ NOVRAM (U29)
         BUFFER   ³³      ³HJK  ÚÄ¿      ÀÙ    ³
      CONTROLLER  ³³ U30  ³     ³S³     PQR    ³
                  ³ÃÄÄÄÄÄÄ´     ³W³            ³
     HOST ADAPTER ³³ U38  ³     ³2³     S      ³
      CONTROLLER  ³³      ³     ÀÄÙ     TÚÄ¿   ³
         (HAC)    ³ÀÄÄÄÄÄÄÙ              ³U³   ³ FIRMWARE PROM (U44)
                  ³        ÚÄ¿           ³4³   ³
                  ³        ³U³          U³4³   ³
                  ³        ³4³          VÀÄÙ   ³
                  ³        ³9³                 ³ 22-BIT IC (U49)
                  À¿       ÀÄÙ  Ú¿            ÚÙ
                   ÀÄÄÄÄÄÄÄÄÄÄÄÄÙÀÄÄÄÄÄÄÄÄÄÄÄÄÙ
             Figure 4-3.  QD21 Disk Controller Assembly
             ============================================

NOTE If you change a switch position on the QD21, or change the configuration
     values in the NOVRAM, you must also reset the QD21 so that the host
     operating system's initialization sequence reads the codes established by
     the switch settings and/or NOVRAM.  To reset the QD21, either toggle
     switch SW1-1 (ON then OFF), or power-down and power-up the the system.  If
     you toggle SW1-1, be sure the system is offline.  Resetting the coupler
     with the system running is likely to crash the system.
          
Table 4-1 defines the function and factory configuration of all switches on the
QD21 controller. The factory configuration switch settings are representative
of most QD21 Disk Controller applications. 

        Table 4-1.  QD21 Switch Definitions and Factory Configuration
ÚÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ¿
³  SW   ³ OFF(0)  ³ ON(1)      ³  FACT  ³     Function             ³ Section ³
ÃÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ´
³ SW1-1 ³ Run     ³ Reset/Halt ³ OFF(0) ³ Runvs.Reset/Halt         ³         ³
³ SW1-2 ³ -       ³ -          ³ OFF(0) ³ MSCP Device Number (LSB) ³ 4.3.3.2 ³
³ SW1-3 ³ -       ³ -          ³ OFF(0) ³ MSCP Device Number       ³ 4.3.3.2 ³
³ SW1-4 ³ -       ³ -          ³ OFF(0) ³ MSCP Device Number (MSB) ³ 4.3.3.2 ³
³       ³         ³            ³        ³                          ³         ³
³ SW2-1 ³ Disable ³ Enable     ³ OFF(0) ³ Loop on Self-Test Error  ³         ³
³ SW2-2 ³ Disable ³ Enable     ³ OFF(0) ³ Automatic Bootstrap      ³ 4.3.3.1 ³
³ SW2-3 ³ -       ³ -          ³ OFF(0) ³ LSI-11 Bus Address       ³ 4.3.1   ³
³ SW2-4 ³ -       ³ -          ³ OFF(0) ³ LSI-11 Bus Address       ³ 4.3.1   ³
³ SW2-5 ³ -       ³ -          ³ OFF(0) ³ LSI-11 Bus Address       ³ 4.3.1   ³
³ SW2-6 ³ 18-bit  ³ 22-bit     ³ OFF(0) ³ 22-Bit Addressing        ³ 4.3.3.3 ³
³ SW2-7 ³ 4 usec  ³ 8 usec     ³ OFF(0) ³ DMA Burst Delay          ³ 4.3.3.4 ³
³ SW2-8 ³ Enable  ³ Disable    ³ OFF(0) ³ Adaptive DMA Mode        ³ 4.3.3.5 ³
ÃÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄ´
³         ON(1) = Closed                                                     ³
³         OFF(0) = Open                                                      ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

Table 4-2 lists the function and factory configuration of all jumpers on the
controller.

       Table 4-2.  QD21 Jumper Definitions and Factory Configuration
     ÚÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
     ³Jumper ³     OUT          ³     IN       ³FACT ³  Comment        ³
     ÃÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
     ³A-B-C-D³ Reserved         ³ Reserved     ³     ³                 ³
     ³ E-F-G ³ Not Used         ³ Not Used     ³ OUT ³ Must be OUT     ³
     ³ H-J-K ³ Not Used         ³ Not Used     ³ OUT ³ Must be OUT     ³
     ³ L-M-N ³ Reserved         ³ Reserved     ³     ³                 ³
     ³  P-Q  ³ Disable Clock    ³ Enable Clock ³ IN  ³ Must be IN      ³
     ³   R   ³ Normal Operation ³ Ground (Test)³ OUT ³ Must be OUT     ³
     ³  S-T  ³ 16K PROM         ³ 32K PROM     ³ IN  ³ Rev E and above ³
     ³       ³                  ³              ³ OUT ³ Rev D and below ³
     ³  U-V  ³ Normal Operation ³ Factory Test ³ OUT ³ Must be OUT     ³
     ÃÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
     ³  FACT = Factory Setting                                         ³
     ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

4.3.1   Disk Controller Bus Address
-----------------------------------
Every LSI-11 bus I/O device has a block of several registers through which the
system can command and monitor that device.  The registers are addressed
sequentially from a starting address assigned to that controller, in this case
an MSCP-class Disk Controller.

The address for the first of the QD21's two LSI-11 bus registers is selected
by DIP switches SW2-3 through SW2-5.  See Table 4-3 for register address switch
settings.  For more information on determining the LSI-11 bus address, see 
Section 3 and Appendix A.

            Table 4-3.  Controller Address Switch Settings
                  ÚÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄ¿
                  ³           ³--- SW2 ---³       ³
                  ³Bus Address³  3  4  5  ³Factory³
                  ³(in octal) ³           ³       ³
                  ÃÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ´
                  ³  772150   ³  0  0  0  ³   *   ³
                  ³  772154   ³  1  0  0  ³       ³
                  ³  760334   ³  0  1  0  ³       ³
                  ³  760340   ³  1  1  0  ³       ³
                  ³  760344   ³  0  0  1  ³       ³
                  ³  760350   ³  1  0  1  ³       ³
                  ³  760354   ³  0  1  1  ³       ³
                  ³  760360   ³  1  1  1  ³       ³
                  ÀÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÙ

4.3.2   Interrupt Vector Address
--------------------------------
The interrupt vector address for the QD21 is programmed into the device by 
the operating system during the MSCP initialization sequence.  See subsection
3.5 for a discussion of vector addresses.

4.3.3   Options
---------------
There are other QD21 options that can be implemented by the user.  These
features are selected by physically installing the option on the PCBA or by
enabling the option using a switch.

4.3.3.1   Automatic Bootstrapping
---------------------------------
The automatic bootstrapping option causes the system to boot automatically from
logical unit 0 through 3 on power-up when the QD21 is at the standard base
address.  To enable this option, set SW2-2 ON and set switches SW1-2 through 
SW1-4 as described in Table 4-4. This option should not be enabled with a 
MicroVAX or in a system that uses an 11/73B CPU module.

      Switch ³  OFF   ³   ON   ³Factory
      ÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      SW2-2  ³Disable ³ Enable ³  OFF

The automatic bootstrapping process requires that the LSI-11 CPU module be 
configured for power-up mode 0.  The following table lists the configuration
settings for several popular LSI-11 CPUs.

       CPU  ³   Configuration Setting
      ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
      11/73A³ Install W3 and W7
      11/23+³ Remove J18-J19 and J18-J17
      11/23 ³ Remove W5 and W6
      11/02 ³ Remove W5 and W6

If the bootstrap device is not powered-up or safe (e.g., it failed its self-
test), the autoboot routine in the QD21 halts the CPU after 1 minute.  This 
causes the CPU to enter Console ODT.  You can then examine the Status and 
Address (SA) register (base address plus 2) for an MSCP error code (Table 5-3) 
and bootstrap the system from another device.

You can bootstrap from a drive supported by a QD21 installed at an alternate
LSI-11 bus address, using any boot process other than autoboot.  In this case, 
be certain that the automatic bootstrap option is disabled (SW2-2 OFF).

4.3.3.2   MSCP Device Number
----------------------------
QD21 switches SW1-2 through SW1-4 specify MSCP device numbers.  The functions
of these switches are dependent on the options you select for your QD21:

   o   If the QD21 is installed at the standard LSI-11 bus address, these 
       switches identify the MSCP device number of the drive from which to
       bootstrap.  The QD21 automatic bootstrap option supports only MSCP 
       units 0 through 3 at the standard address.

   o   If the QD21 is installed at an alternate LSI-11 bus address, these 
       switches identify the MSCP device number of the first drive supported by
       that alternate QD21.  The first drive supported by the QD21 at an 
       alternate address may be drive 0 through 7.

4.3.3.2.1   Logical Unit to Boot From
-------------------------------------
If the QD21 automatic bootstrapping option is enabled (SW2-2 ON) and the 
QD21 is at the standard LSI-11 bus address (772150), switches SW1-2 through
SW1-4 define the MSCP device number of the drive from which the QD21 
bootstraps.  By using these switches, you may select one of four logical units 
to bootstrap from. Table 4-4 defines the MSCP device numbers selected by
switches SW1-2 through SW1-4 if the QD21 is at a standard address.

                 Table 4-4.  Bootstrap MSCP Device Number
            ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ¿
            ³ Bootstrap MSCP ³ ------- SW1 ------- ³ Factory ³
            ³ Device Number  ³   2      3      4   ³         ³
            ³                ³ (LSB)         (MSB) ³         ³
            ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ´
            ³      0         ³   0      0      0   ³    *    ³
            ³      1         ³   1      0      0   ³         ³
            ³      2         ³   0      1      0   ³         ³
            ³      3         ³   1      1      0   ³         ³
            ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÙ

4.3.3.2.2   First Logical Unit Number for an Alternate Address
--------------------------------------------------------------
If your QD21 is installed at an alternate address, switches SW1-2 through 
SW1-4 select the MSCP device number of the first drive supported by the QD21.
MSCP device numbering schemes may vary by DEC operating system (see subsection
3.4.2.2).  Table 4-5 defines the MSCP device numbers selected by switches SW1-2
through SW1-4 if the QD21 is at an alternate address.

    Example 4-1:
    Your system operates under RSX-11M-PLUS and has two QD21 Disk 
    Controllers.  The first QD21 is at the standard base address for MSCP
    controllers (772150) and supports three logical drives: Unit 0, Unit 1,
    and Unit 2.  The second QD21 is at an alternate base address and supports
    two logical drives.  RSX-11M-PLUS requires that the first drive on the
    alternate QD21 have an MSCP device number of 3 and that the second drive 
    have an MSCP device number of 4.  On the alternate QD21, set switches 
    SW1-2 in the ON position, SW1-3 in the ON position, and SW1-4 in the OFF 
    position to specify a MSCP device number of 3 for the first drive.

    This example would also apply if the first MSCP controller were a DEC MSCP
    controller with three logical drives. 


       Table 4-5.  MSCP Device Number for the First Drive Supported by a 
                         QD21 at an Alternate Address
                 ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                 ³ Starting MSCP ³  ------- SW1 -------  ³
                 ³ Device Number ³     2      3     4    ³
                 ³               ³   (LSB)        (MSB)  ³
                 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
                 ³       0*      ³     1     0      0    ³
                 ³       1       ³     0     1      0    ³
                 ³       2       ³     1     1      0    ³
                 ³       3       ³     0     0      1    ³
                 ³       4       ³     1     0      1    ³
                 ³       5       ³     0     1      1    ³
                 ³       6       ³     1     1      1    ³
                 ³       7       ³     0     0      0    ³
                 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
 *Used to bootstrap a drive from the QD21 at an alternate LSI-11 bus address. 
          
4.3.3.3   22-Bit Memory Addressing
----------------------------------
The 22-bit addressing capability is a standard option for the QD21 and is 
supplied with the QD21 as a kit, part number QD0111302.  To enable 22-bit 
addressing, install the single 7438 IC in socket U49 on the QD21 PCBA and set
SW2-6 ON (1).  22-bit addressing must be enabled with MicroVAX systems. 

   CAUTION  Some manufacturers of LSI-11 bus backplanes use the backplane lines
            now devoted to extended addressing for power distribution.  
            Installing a QD21 with the extended addressing option in such a 
            system will damage the option IC.  Before installing the option,
            confirm that there is neither positive nor negative potential 
            between lines BC1, BD1, BE1, BF1, and logic ground.  A QD21 
            without the extended addressing option will not be damaged if power
            is present on those lines.
          
4.3.3.4   DMA Burst Delay
-------------------------
The QD21 firmware design includes a switch-selectable DMA burst delay to 
avoid data-late conditions.  Switch SW2-7 selects either a 4- or 8-microsecond 
delay between DMA bursts.  Even with the QD21 adaptive DMA, some applications
may require a longer burst delay to allow other devices adequate time on the 
bus.

          Switch³  OFF   ³   ON   ³Factory
          ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
          SW2-7 ³ 4 usec ³ 8 usec ³  OFF

4.3.3.5   DMA Adaptive Mode
---------------------------
Depending on the other devices on the bus and their priority, the QD21 may 
use more or less bus time than optimal for your application.  The QD21 allows
you to modify its DMA operations by disabling adaptive DMA.  If adaptive DMA is
disabled, the host processor programs the DMA burst length to a maximum of 8 
words per burst.

When adaptive DMA is enabled (SW2-8 OFF), the QD21 monitors the LSI-11 bus 
for other pending DMA requests and suspends its own DMA activity to permit 
other DMA transfers to occur.  If the QD21 is not getting the bus time your 
application requires, you may want to disable the adaptive DMA.  When adaptive 
DMA is disabled, the QD21 performs a burst transfer of 8 words of less, 
relinquishes the bus, then performs another DMA burst transfer.

      Switch³      OFF     ³     ON       ³Factory
      ÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      SW2-8 ³ Enable       ³ Disable      ³  OFF
            ³ Adaptive DMA ³ Adaptive DMA ³


   NOTE  If you are using the QD21 with adaptive DMA enabled in a 
         MicroVAX II subsystem, be aware that the CPU module uses DMA requests 
         to gain use of the bus to service device interrupts and may interfere 
         with the QD21's bus access.  You may consider disabling adaptive DMA
         for improved throughput.

4.4   Physical Installation
---------------------------
This section provides instruction for system preparation, slot selection, and
mounting the QD21.

4.4.1   System Preparation
--------------------------
To prepare your CPU to accept the QD21, use the following procedures:

  o  MICRO/PDP-11 and MicroVAX I and II Preparation:

     1. Power down the system by switching OFF the main ac breaker.

     2. Remove the rear cover from the chassis so that the patch panel is 
        exposed.  The rear cover is held on by snap pads.  Grasp the cover at 
        the top and bottom, and pull straight back.

     3. Loosen the captive screws from the patch panel using a standard 
        screwdriver.

     4. Remove the patch panel.

     5. Find the flat-ribbon cable that connects the CPU module to the patch 
        panel.  For easier board installation, you may disconnect the CPU
        flat-ribbon cable from the patch panel.

  o  LSI-11 Series Preparation:

     1. Power down the system by switching OFF the main ac breaker.

     2. Remove the cover from the chassis so that the backplane is exposed.

Do not replace the covers or patch panels until the installation is verified
(subsection 4.8).

4.4.2   Slot Selection
----------------------
The QD21 may be assigned to any desired slot because it uses the LSI four-
level interrupt scheme to perform distributed interrupt arbitration.

Be sure to find out whether your backplane is straight or serpentine and choose
a slot accordingly.  On straight backplanes, the QD21 must be plugged into
connectors A and B, since connectors C and D carry no signals.  On a serpentine
backplane, the QD21 can be plugged into either connectors A and B or 
connectors C and D.

There must be no unused slots, however, between the CPU and the QD21.  If you
have a DEC RQDX1 in your backplane, be sure to install the QD21 in front of 
the RQDX1; not all RQDX1 controllers pass grant signals.

4.4.3   Mounting
----------------
The QD21 Disk Controller PWB should be plugged into the LSI-11 backplane with
components oriented in the same direction as the CPU and other modules.  Always
insert and remove the boards with the computer power OFF to avoid possible 
damage to the circuitry.  Be sure that the board is properly positioned in the 
throat of the board guides before attempting to seat the board by means of the 
extractor handle.

4.5   ESDI Disk Drive Preparation
-----------------------------------
The disk drive(s) must have an ID plug or address selection switches properly
configured and the drive set for either hard or soft sectoring.  If you are
using hard sectored drives, remember that in the autoconfigure mode the drive
sector setting is overridden by the set bytes per sector command from the
controller.  If you are using the NOVRAM values, the drive sectoring must be
set to match the NOVRAM values.

4.5.1   Drive Placement
-----------------------
Unpack and install the disk drives according to the manufacturer's instructions
Install the disk drives in their final positions before beginning the 
installation of the QD21.  This positioning allows the I/O cable routing and 
length to be accurately judged.

4.5.2   Sectoring
-----------------
The QD21 supports both hard and soft sectored drives.  The drive parameter 
tables in Appendix C recommend either soft or hard sectoring; set jumpers or
switches as indicated in the drive manufacturer's manual.  In general, if a 
drive is capable of both hard and soft sector format, hard-sectoring is 
preferred as long as the number of hard sectors does not reduce the possible
drive capacity.

4.5.3   Drive Numbering
-----------------------
A unique address must be selected for each drive.  The logical unit number is
determined by the address given to the drive.  See subsection 3.2.2.

Drive manufacturers use jumpers, switches, or ID plugs to select addresses.
Consult the appropriate drive manual for the exact procedure.

4.5.4   Spindle Motor Spin-up
-----------------------------
Most ESDI drives have a spindle motor control option which allows the the drive
controller to control the timing of the drive spindle motor spin-up.  Emulex
recommends that you allow the QD21 controller to start the spin-up of the 
drive(s).  If there is more than one drive, the QD21 issues the spin-up 
commands to each drive sequentially.  This will minimize any power surge on 
multiple drive systems.  

4.5.5   Termination
-------------------
Terminator power is supplied by the drive.  The terminated drive must therefore
have power applied in order for termination to be effective.  Otherwise,
indeterminate results will occur.

Only the last drive in the string is terminated.

4.6   Cabling
-------------
The QD21 Disk Controller interfaces with each ESDI disk drive that it controls
via one 34-line control cable and a 20-line data cable.  The control cable 
originates from connector J3 on the QD21 and is daisy-chained to all of the 
supported drives, terminating on the last drive.  Maximum cumulative cable 
length for the control cable is 10 feet (3 meters).  The data cables originate
from connectors J1 and J2 on the QD21; each data cable is connected directly 
from the QD21 to each supported disk drive.  Maximum cable length for each data
cable is 10 feet (3 meters).

Emulex offers the QD21 Internal Cabling Kit (P/N QD2113001) which allows you to
install the QD21 and the ESDI disk drive(s) in the CPU cabinet. Table 4-6 lists
the components of this cabling kit; Figure 4-4 shows basic cable installation.

In addition, Emulex offers the QD21 External Cabling Kit (P/N QD0113003) which
allows you to install the QD21 in the CPU cabinet and the ESDI disk drives in a
separate cabinet; instructions for installing this kit are described in the 
QD01/QD21 Cabling Kit Instruction Sheet (P/N QD0152401).

             Table 4-6.  QD21 Internal Cabling Kit (P/N QD2113001)
             ÚÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
             ³Qty³ Part Number³Cable Length³  Cable Description   ³
             ÃÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
             ³ 2 ³QU0111202-01³   3 ft     ³20-conductor, flat    ³
             ³   ³            ³            ³ESDI data interface   ³
             ³   ³            ³            ³                      ³
             ³ 1 ³QU0111201-01³   1 ft     ³34-conductor, flat    ³
             ³   ³            ³            ³ESDI control interface³
             ³   ³            ³            ³daisy-chain           ³
             ³   ³            ³            ³                      ³
             ³ 1 ³QU0111203-01³   1 ft     ³34-conductor, flat    ³
             ³   ³            ³            ³ESDI control interface³
             ÀÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

Table 4-7 lists the components that are required to construct both control and 
data cables.

                 Table 4-7.  Interface and Cable Components
    ÚÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
    ³       ³            ³             Cable Components                  ³
    ³Cnctr  ³ Controller ³ Header   Control        Cable Type      Drive ³
    ³Number ³ Function   ³  Type     Cnctr     Unshield Shielded   Cnctr ³
    ÃÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
    ³J3     ³ Control    ³  3594     3414      3801/34  3517/34     3463 ³
    ³J1/J2  ³ Data       ³  3592     3421      3801/20  3517/20     3461 ³
    ÃÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
    ³Cnctr = Connector                                                   ³
    ³All component numbers are 3M.  Equivalents may be used.             ³
    ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


                                                               UNIT 0
                               CONTROL CABLE               ÚÄÄÄÄÄÄÄÄÄÄÄ¿
                  ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍËÍÍÍÍÍÍÍÍÍÍÍÍ³¿    ESDI  ³
        QD21      º            DATA CABLE     º            ³Ù    DISK  ³
    ÚÄÄÄÄÄÄÄÄÄÄÄÄÄ×Ä¿J1        ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄºÄÄÄÄÄÄÄÄÄÄÄÄ³]    DRIVE ³
    ³          J3Úº[ÅÄÄÄÄÄÄÄÄÄÄÙ              º            ÀÄÄÄÄÄÄÄÄÄÄÄÙ
    ÆÍ           À¼[ÅÄÄÄÄÄÄÄÄÄÄ¿              º(DAISY CHAINED)..TERMINATOR
    ³               ³J2        ³              º            ÚÄÄ:ÄÄÄÄÄÄÄÄ¿
    ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ          ³              ÈÍÍÍÍÍÍÍÍÍÍÍÍ³¿ º  ESDI  ³
                               ³DATA CABLE                 ³Ù    DISK  ³
                               ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ³]    DRIVE ³
                                                           ÀÄÄÄÄÄÄÄÄÄÄÄÙ
                                                               UNIT 1
                        Figure 4-4.  Drive Cabling
                        ==========================

The Federal Communications Commission (FCC) has mandated that equipment that
uses radio-frequency signals in its operation must limit the amount of 
electromagnetic interference (EMI) that it radiates.  Most manufacturers, 
including DEC, limit EMI by building continuous metal shields into their 
equipment cabinets.

When installing the QD21 and its disk drives, you must take care that the 
shield that DEC has built into its equipment cabinets is not defeated.

The routing of the cables that connect the QD21 and its disk drives can have a 
major impact on the amount of EMI that is radiated by the subsystem (the 
combination of the QD21 and its drives), especially if the QD21 and the disk
drives are installed in separate cabinets.

As noted in subsection 4.1.3, the QD21 and its ESDI disk drive(s) can be
installed in either of two configurations:

  o  With both the QD21 Disk Controller and the ESDI disk drive(s) that it
     supports mounted in the same cabinet

  o  With the QD21 mounted in the CPU cabinet and the ESDI disk drive(s)
     mounted in a separate cabinet

When the QD21 and the ESDI disk drive are installed in the same cabinet, it is
possible that the cabinet itself provides sufficient shielding.  In such cases,
it is not usually necessary to shield the cable that carries the ESDI interface
between the QD21 and the ESDI peripherals.

      NOTE
      If the cabinet in which the QD21 and LSI-11 CPU are installed was
      manufactured before 1 October 1983, it may not provide sufficient
      shielding or filtering to prevent excessive RFI radiation or
      conduction.  In case of complaint, it is the operator's responsibility
      to take whatever steps are necessary to correct the interference.
          
If the ESDI disk drives are mounted in a separate cabinet from the QD21 Disk 
Controller, then the cables that connect the QD21 to the drives should probably
be shielded, because they run outside the shielded cabinet environment.

In addition, you should take special care that the integrity of the shield is 
maintained where the cables pass through it.  Usually, designers use clamps 
that effectively connect the cable shielding to the cabinet shield.


                         Section 4 (continued)
                         ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ

4.7   NOVRAM Loading, Disk Formatting, and Testing
--------------------------------------------------
After physically installing the QD21, several steps are required to prepare
the subsystem for operation. They are:

  o  Loading the drive configuration into the NOVRAM
  o  Formatting and verifying the media
  o  Testing the subsystem

The QD21 disk controller firmware incorporates a self-contained set of disk 
preparation and diagnostic utilities, called firmware-resident diagnostics
(F.R.D.).  F.R.D. provides several important disk preparation functions, 
including the ability to configure the controller NOVRAM, format the drive, 
test the disk surface and replace defective blocks, and perform reliability 
testing of the attached disk subsystem.  These utilities allow you to 
communicate directly with either CRT or hardcopy devices connected to an LSI-11
or MicroVAX console port.

The basic application of F.R.D. is in preparing MSCP disk drives for use in 
your subsystem.  Before data can be stored on a drive, the disk must be 
formatted and any bad blocks identified.  F.R.D. provides options that allow 
you to perform these functions.  You use NOVRAM configuration options to set 
and review your drive parameter values.

The steps involved in disk preparation are formatting the drive and then 
verifying that each logical block is good.  Because the QD21 automatically 
replaces any block listed in the manufacturer's defect list, it is unlikely 
that the verify operation will find any additional bad blocks.  However, 
F.R.D. supports both automatic and manual block replacement operations to 
allow for replacing blocks not contained in the MDL or for use in the event 
that the MDL has been destroyed.

Automatic replacement, or blanket bad block replacement, is a feature of 
several F.R.D. options.  With this feature, you can format a drive, verify, and
replace any bad blocks in one step.  During this format/verify operation, bad 
blocks are displayed in logical block number (LBN) format.  If replacement is 
enabled, the blocks are replaced automatically.

Manual bad block replacement is a separate option.  This option allows you to 
identify specific bad blocks to be replaced.  In addition, you can identify the
blocks in Bytes From Index (BFI) format or in LBN format.  Using BFI format 
eliminates the calculation required for LBN.  This is most often useful in 
replacing blocks identified as bad in the manufacturer's defect list when that
list no longer exists on the drive. 

BFI replacement must be done before any LBN replacement.  Once LBN replacement
occurs, the BFI values are no longer valid.  

There are several ways you can use F.R.D. options to format and verify your 
disk.  The method you choose depends on whether you:

  o  Have formatted this disk
  o  Want to replace blocks using BFI or LBN information
  o  Want to preserve data on this disk

Each method is described below. The options listed are on the F.R.D. main menu.
Use them in the order they are listed. (F.R.D. options are described in section
4.8.)

If this is the initial format of a disk with a valid MDL and you want to 
replace those defects that are outside of the MDL, use:

  o  Option 2, Format and Verify with replacement enabled

If this is the initial format of a disk that contains no usable defect list, 
and you want to replace manufacturer's detected defects from the hardcopy 
list, use:

  o  Option 1, Format
  o  Option 7, Replace Block using BFI format
  o  Option 3, Verify with replacement enabled

If this disk is formatted and you want to preserve data and obtain a list of 
bad blocks, use:

  o  Option 4 with replacement disabled

4.7.1   F.R.D. Conventions
--------------------------
F.R.D. uses the following keyboard conventions:

   <CR>       required to terminate operator inputs

   <Ctrl C>   aborts the current operation and returns to the main menu


A minimum delay of 10 seconds may occur between the <Ctrl C> and the next 
display.  During some verify operations, the delay may be considerably longer
because the abort is delayed until the successful completion of the current 
command.  In this case, a screen message informs you of the delay.

In this section, operator responses to F.R.D. prompts appear in bold print. The
symbols used in this section are listed below with their meanings:

         <CR>        carriage return key
         <LF>        line feed key
         <Ctrl C>    Ctrl key and the letter C pressed at the same time

4.7.2   Starting F.R.D. on a MicroVAX I
---------------------------------------
F.R.D. is started by issuing a special command sequence via console ODT.  To
start F.R.D. on a MicroVAX I, first apply power to the system.  Put the system
in console mode, then enter the following commands via the host console in 
response to the >>> prompt:

   >>>D/P/W  2000XXXX 1<CR>           !INIT CONTROLLER
   >>>E/P/W  2000YYYY<CR> 900 OR B00  !STEP ONE FROM QD21
   >>>D/P/W  2000YYYY 3003<CR>        !ENABLE SPECIAL MODE
   >>>E/P/W  2000YYYY<CR> 0100        !ACK SPECIAL MODE
   >>>D/P/W  2000YYYY 4401<CR>        !UPLOAD DRIVER
   >>>E/P/W  2000YYYY<CR> 0400        !UPLOAD DONE
   >>>S      80<CR>                   !START DRIVER

NOTE:  XXXX and YYYY are offsets dependent on the address of the QD21 
controller.  See Table 4-8 for the available values.

4.7.3   Starting F.R.D. on a MicroVAX II
----------------------------------------
F.R.D. is started by issuing a special command sequence via console ODT.  To
start F.R.D. on a MicroVAX II, first apply power to the system.  Put the system
in console mode, then enter the following commands via the host console in 
response to the >>> prompt:

   >>>I                               !BUS INIT
   >>>D/P/W  20001F40 20<CR>          !ENABLE MEMORY
   >>>D/P/L  20088000 80000000<CR>    !SETUP MAP 0
   >>>D/P/L  20088004 80000001<CR>    !SETUP MAP 1
   >>>D/P/W  2000XXXX 1<CR>           !INIT CONTROLLER
   >>>E/P/W  2000YYYY<CR> 900 OR B00  !STEP ONE FROM QD21
   >>>D/P/W  2000YYYY 3003<CR>        !ENABLE SPECIAL MODE
   >>>E/P/W  2000YYYY<CR> 0100        !ACK SPECIAL MODE
   >>>D/P/W  2000YYYY 4401<CR>        !UPLOAD DRIVER
   >>>E/P/W  2000YYYY<CR> 0400        !UPLOAD DONE
   For MicroVAX II:
   >>>S 80<CR>                        !START DRIVER
   For GPX Workstation:
   >>>S 82<CR>                        !START DRIVER

NOTE:  XXXX and YYYY are offsets dependent on the address of the QD21 
controller.  See Table 4-8 for the available values.

                     Table 4-8.  MicroVAX Offsets
                  ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄ¿
                  ³ CONTROLLER  ³  XXXX  ³  YYYY  ³
                  ³ BUS ADDRESS ³        ³        ³
                  ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
                  ³ 772150      ³  1468  ³  146A  ³
                  ³ 772154      ³  146C  ³  146E  ³
                  ³ 760334      ³  00DC  ³  00DE  ³
                  ³ 760340      ³  00E0  ³  00E2  ³
                  ³ 760344      ³  00E4  ³  00E6  ³
                  ³ 760350      ³  00E8  ³  00EA  ³
                  ³ 760354      ³  00EC  ³  00EE  ³
                  ³ 760360      ³  00F0  ³  00F2  ³
                  ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÙ

4.7.4   Starting F.R.D. on an LSI-11 System
-------------------------------------------
To start F.R.D. on an LSI-11 system, first halt the processor.  Then enter the 
following commands in response to the ODT prompt (@):

      @ 177xxxxx/ 000000 1 <LF>
      @ 177yyyyy/  4400 or 5400 30003 <CR>
      @/000400 42000<CR>
      @ 177yyyyy/ 2000 <CR>!TEST FOR 2000
      @ 200G

NOTE:  XXXX and YYYY are offsets dependent on the address of the QD21 
controller.  See Table 4-9 for the available values.

                      Table 4-9. LSI-11 Offsets
               ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄ¿
               ³ CONTROLLER   ³  XXXX   ³  YYYY   ³
               ³ BUS ADDRESS  ³         ³         ³
               ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄ´
               ³   772150     ³  72150  ³  72152  ³
               ³   772154     ³  72154  ³  72156  ³
               ³   760334     ³  60334  ³  60336  ³
               ³   760340     ³  60340  ³  60342  ³
               ³   760344     ³  60344  ³  60366  ³
               ³   760350     ³  60350  ³  60352  ³
               ³   760354     ³  60354  ³  60356  ³
               ³   760360     ³  60360  ³  60362  ³
               ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÙ

When the appropriate start procedure is completed, F.R.D. identifies itself by 
displaying the controller type and firmware revision.  Then, it displays the 
menu options.  See subsection 4.8 for more information on F.R.D. options.

4.7.5   Terminating F.R.D.
--------------------------
To terminate F.R.D., choose one of the following:  

  o  Press the BREAK key
  o  Reinitialize the system, or
  o  Halt the CPU.

You can restart the diagnostics from a halted condition if you have not changed
the memory contents.  On an LSI-11 system, enter 200G at the ODT prompt.  On a
MicroVAX system, enter S 80.

4.8   F.R.D. Options
--------------------
F.R.D. is an interactive, menu-driven utility.  This section describes the 
function of each option on the F.R.D. main menu.  The menu appears as follows:

      Program Option Menu

      1  - Self-test loop
      2  - Format
      3  - Verify
      4  - Format and verify
      5  - Data reliability test
      6  - Format, verify, and data reliability test
      7  - Read only test
      8  - List known units
      9  - Replace block
      10 - Display Novram
      11 - Edit / Load Novram

      Enter option number:

The main menu and each submenu prompt for required input.  When you enter a 
valid selection, the next menu displays or F.R.D. performs the selected option.
If you make an invalid entry, F.R.D. rejects it, displays an error message, and
reprompts.

Based on the nature of the MSCP emulation being performed, some operations may
produce an observable delay when performed on previously unformatted drives.
This delay is approximately 30 seconds. 

When an option is finished, F.R.D. displays the prompt "Hit any key to 
continue" and waits for you to do so before returning to the main menu.

4.8.1   Option 1 - Self-test Loop
---------------------------------
The Self-test Loop option detects intermittent hardware failures that have 
already passed through the first self-test.  The LED indicators on the QD24 
front panel will blink when a pass has compeleted.  If an error occurs, the 
self-test loop option stops and reports an error; the LEDs on the front panel 
display the error code.  A description of the error codes is displayed on the
host console device.  This option may be aborted by <Ctrl C>

4.8.2   Option 2 - Format
-------------------------
The Format option is used to initially format a drive.  The operation writes 
sector headers; initializes the drive's replacement caching tables (RCT), and 
replaces any defects listed in the MDL.  It is used to format a virgin drive, a
drive that has been determined to contain unusable data, or a drive with a 
format that is improper to use with a particular controller.  

If a type 2 drive is being formatted (configuration parameters are read from 
the drive), F.R.D. prompts for spiral offset.

After formatting, the drive contains a valid RCT with a serial number you 
specified.  During format, F.R.D. attempts to read and use the MDL.  F.R.D. 
displays a message if the MDL cannot be read.  If portions of the MDL are bad, 
F.R.D. uses whatever good information can be extracted.

It is possible that either type 1 or type 2 drives might have so many multiple 
sector/track defects that the default number of spare cylinders allocated for
replacement usage is not large enough.  If the number of defects in the MDL 
exceeds the replacement area allocated, you will be alerted by a message 
stating that the present value doesn't allow formatting with MDL and how many
spare cylinders are required to accomodate the MDL.  This number of spare 
cylinders includes two additional cylinders for future bad spots.  If this
occurs, you have two choices:

   Drive Type Code 2.  Continue to format without MDL, running two passes of
   verify and 10 passes of reliability to remove pattern sensitive bad blocks.

   Drive Type Code 1.  Change to type code 1 and change the number of spare 
   cylinders as required by the message from F.R.D; restart the format. 

You will be notified if a drive has been formatted without the MDL; this will
occur if a drive's MDL cannot be read and/or if there is an insufficient number
of spare cylinders.  You have the option to let the formatting continue or to 
abort using <Ctrl C).

4.8.3   Option 3 - Verify
-------------------------
The Verify option Write/Read exercises all user-available blocks.  F.R.D. uses 
four worst-case data patterns to find and replace pattern-sensitive blocks not
found in the drive defect list.  It asks for the logical unit number (LUN) of 
the drive to be verified.  After you enter the LUN, F.R.D. prompts for the 
number of write/read passes. 

Verify operations are performed on 120 logical blocks at a time. Logical blocks
are referenced by logical block number (LBN).

During Verify operations, F.R.D. disables all controller error recovery 
capabilities so that a sector is replaced for any repeatable single bit error.
Each data pattern is run until error-free for a single pass, ensuring that
replacement blocks are also verified.

When a block is encountered that cannot be accessed because of header or data 
field errors, the Logical Block Number in error displays.  Because the failing
pattern may not be the first pattern, it is possible that replacement blocks 
may not be tested with all patterns. For this reason, Emulex recommends running
at least two Verify passes over all 4 data patterns.

The Verify option has many features which allow you to enable full error 
description.  When Error Description is enabled, it reports the type of error 
that occurs on the bad blocks.  If a drive is producing an excessive number of
bad blocks, this feature helps determine the kinds of errors responsible.

The Verify option also offers a bad block replacement feature which, when 
enabled, replaces any bad blocks using the appropriate technique.

At the end of all testing or when you enter a <Ctrl C>, F.R.D. reports the 
number of bad blocks detected by the Verify operation. There will be no message
if the Verify option does not detect any errors.

4.8.4   Option 4 - Format and Verify
------------------------------------
This option formats a drive, then tests the surface to replace pattern-
sensitive and defective sectors.  It performs both of the operations that are 
available separately with options 2 (Format) and 3 (Verify).  This option also
offers a bad block replacement feature which, when enabled, replaces any bad 
blocks found during the verify operation. 

4.8.5   Option 5 - Data Reliability Test
----------------------------------------
This option allows you to thoroughly test your subsystem.  The reliability test
uses Write, Write/Check, and Read functions to test the controller-to-drive
portion of the subsystem. In addition, an independent DMA operation between the
host memory and the controller tests the host/controller interface.

The test defaults to two reserved diagnostic cylinders so that user data will 
be protected; a test of the full pack is your option.  To run the reliability 
test indefinitely, select 0 (zero) passes.

If the test encounters errors, F.R.D. displays text error messages.  These
messages are primarily for use by Emulex technical support personnel.

4.8.6   Option 6 - Format, Verify, and Data Reliability Test
------------------------------------------------------------
This option combines options 2 (Format), 3 (Verify), and 5 (Data Reliability
Test).  This option automates the initialization and testing of drives, since 
you can select multiple drives and activate the data reliability test without
having to wait for the format and verify options to complete.  The format and 
verify portions of this option run in the order of the drives selected.  Drives
with hard faults are dropped and the sequence moves to the next drive in the 
list.  The reliability portion of this option runs simultaneously on all
selected drives. 

4.8.7   Option 7 - Read Only Test
---------------------------------
This option causes all the user-available blocks on the selected drive to be 
Read-only, not Write/Read, during the Verify pass.  When a block is encountered
that cannot be accessed because of header or data field errors, the utility 
displays the Logical Block Number.

The Read Only Test option also offers a bad block replacement feature, which, 
when enabled, replaces any bad blocks.  Because F.R.D. runs with ECC disabled 
and does not cache any read data, no corrected data is available to put in the 
replacement block.  This means that even though the defective block is replaced
and no forced error flag is set in the replacement sector, the data is nonvalid

   CAUTION  This may cause problems if the replaced blocks contain executable
            program files.  For this reason, you should back up sensitive data
            before running this option with the replacement feature enabled.
          
This option is usually used after the drive is formatted.  However, if you plan
to manually replace the bad blocks identified in the manufacturer's defect 
list, be certain to do so before using Option 7 with replace enabled.

4.8.8   Option 8 - List Known Units
-----------------------------------
This option causes the program to list all the drives that are configured in
the NOVRAM.  Only those units that can be selected by the controller are listed
as available.

A user size (in 512-byte blocks) and a media type I.D. are listed with all 
drives found by this option.  The user size does not include RCT area, 
diagnostic cylinders, designated or hidden spare tracks or blocks, etc.

In addition, this option displays the attached drive's physical geometry.  This
display includes all areas of the disk. If the device size in logical blocks is
calculated from this data, the number will be larger than the displayed user 
size.  The difference is the number of LBNs used for RCT, diagnostic cylinders,
spares, etc.

4.8.9   Option 9 - Replace Block
--------------------------------
This option allows you to replace a specific bad block or group of blocks 
without using the blanket replacement feature found in the Verify and Read Only
options.  You choose to identify either logical blocks (entered in decimal MSCP
Logical Block Number format) or Bytes From Index (as listed in the manufactur-
er's defect list), then enter the block to be replaced. If you specify LBN, then
you will be prompted to enter the block to be replaced. If you specify BFI, you
will be prompted for the number of bytes from index, then to enter the length
in bits.

BFI replacement eliminates the calculation required to translate BFI to LBN 
format.  F.R.D. requires the cylinder, track, and bytes from index of the 
defect for each BFI entry.  When you initiate replacement, F.R.D. prompts for
the number of bytes from index.  As soon as you enter this value, you are 
prompted to enter the length in bits, then F.R.D. begins replacing blocks. 

LBN replacement allows you to replace blocks identified as bad during the 
format operation, when they are identified in LBN format by older versions of 
DEC operating systems which do not support host-initiated replacement.  

If you are using both types of replacement, BFI replacement must be complete 
before LBN replacement is begun.  Further, BFI replacement must be complete 
before the blanket bad block replacement feature of other options is enabled.

Emulex recommends that you run the Verify option after the replacement option 
is complete.  The Verify option runs test patterns that may detect any pattern-
sensitive blocks. 

4.8.10   Option 10 - Display NOVRAM
-----------------------------------
This option displays the current contents of the NOVRAM for your drives.  The 
information displayed depends on the type code entered in the NOVRAM.  For type
1 drives, this option displays the current NOVRAM parameter values.  For type 2
drives, this option lists the drive as type 2 with parameters read from the 
drive.
 
4.8.11   Option 11 - Edit/Load NOVRAM
-------------------------------------
This option allows you to enter the drive configuration parameters into the 
controller.    If a drive type code of 1 is specified, F.R.D. prompts you for 
the required drive parameters.  If a drive type code of 2 is specified, the 
controller obtains configuration parameters from the drive.

4.9   Drive Configuration Parameters
------------------------------------
When you edit or load NOVRAM configuration parameters, you are asked to enter 
the values required for your configuration.  This section describes each 
parameter and states the range of valid entries for each.  The required values
for each drive supported by Emulex are listed in Appendix C.

You begin loading NOVRAM parameter values by selecting Option 11 from the 
F.R.D. main menu.  F.R.D. then displays each parameter, one at a time.  The
parameter displays with a range of valid entries and a default value.  Enter
the appropriate value (in decimal) or simply press the return key to accept the 
default value (the last value entered).  The next parameter then displays.

4.9.1   Type Code
-----------------
This parameter indicates the type of disk drive.  Valid values are 1 and 2.  If
you enter 1, the controller expects to find drive configuration information
contained in the NOVRAM.  F.R.D. then displays each parameter for you to enter 
the values.

If you enter 2, the controller obtains the drive configuration information from
the drive.  In this case, the only other parameter value you enter for this 
drive is the spiral offset, which is entered when you initiate a format option 
during formatting.  The spiral offset parameter is saved on the disk drive.  
Default values are used for the number of spare sectors per track (1) and the
number of alternate cylinders (2).

     NOTE
     A compatibility issue may exist if you define a drive as Type 1, then
     later redefine it as Type 2, even if the NOVRAM values you entered match
     those read from the drive.
         
     If a drive is in hard sector mode, the controller is configured for
     Type 2 drives, and you want to switch the drive to Type 1, then the
     drive must first be powered down.  This allows it to switch from Type 2
     commanded Bytes per Sector to the number of bytes per sector
     determined by the drive sector switches or jumpers.  This problem
     may be eliminated by setting the drive jumpers or switches to match
     the number of sectors determined by the Type 2 calculations.
         
4.9.2   Number of Units of this Type
------------------------------------
This parameter specifies the quantity of attached physical disk drives that use
the NOVRAM parameters that follow.  Valid values are 1 and 2.  If you enter 1, 
the utility uses a separate set of parameter values for each drive.  In this
case, it prompts for parameter values for the second drive. If you enter 2, the
same parameter values are used for both drives.

4.9.3   Number of Sectors per Track
-----------------------------------
This parameter specifies the total number of physical sectors per track, 
including spares.  The valid range is from 1 through 255.

4.9.4   Number of Heads
-----------------------
This parameter specifies the number of data heads per physical drive. The valid
range is from 1 through 63.

4.9.5   Number of Cylinders
---------------------------
This parameter specifies the total number of physical cylinders per drive, 
including spares.  The valid range is from 1 through 4,095.

4.9.6   Number of Spare Sectors per Track
-----------------------------------------
This parameter specifies the number of spare sectors reserved per track. Emulex
recommends a value of 1; larger values will unnecessarily reduce the capacity
of the drive.  The default value of 1 is used if you select a type code of 2.  

4.9.7   Number of Alternate Cylinders
-------------------------------------
This parameter specifies the number of spare cylinders per physical drive.  The
valid range is from 0 through 15. At least one cylinder must be specified as an
alternate.  (If spare sectors are specified, the sector replacement algorithm 
needs one track for working space.)  Emulex recommends a value of two; this is 
the default value if you select a type code of 2.

If Split Code 1 is used, you must specify twice the normal number of alternate 
cylinders because they are divided evenly between the two logical drives.  A
minimum of 2 alternate cylinders must be specified if block replacement is to 
function with a cylinder split.

4.9.8   Configuration Bits
--------------------------
This parameter defines some additional configuration parameters of the drive.  
This parameter has a 4-bit field with a valid range from 0 through 15.

If you selected type code 2 for this drive, the configuration information is 
read from the drive and you will not need this information.     

If you selected type code 1 for this drive and your subsystem includes a drive 
that Emulex supports, refer to Appendix C for the value to enter for this 
parameter.  If your drive is not supported by Emulex, refer to the drive
manufacturer's manual for drive requirements, then enter the appropriate values
as defined below:

Bit 0: This bit is 0 if the drive is hard sectored and 1 if the drive is soft 
sectored.

Bit 1: This bit specifies whether or not the drive can perform early or late 
data strobe operations.  The valid range for this bit is 0 or 1.  If this bit
is 0, the drive cannot perform early or late data strobe operations.  If this 
bit is 1, the drive is capable of performing early or late data strobe 
operations.

Bit 2: This bit specifies whether or not the drive is capable of head offset 
operations.  The valid range for this bit is 0 or 1.  If this bit is 0, the 
drive cannot perform head offset operations.  If this bit is 1, the drive is 
capable of performing head offset operations.

Bit 3: This bit specifies whether or not the drive negates the Command Complete
signal during a head select operation.  The valid range for this bit is 0 or 1.
If this bit is 0, the Command Complete signal remains on during a head select. 
If this bit is 1, the Command Complete signal is negated during a head select.

The decimal value for this parameter is calculated from these binary bits.  
Table 4-10 shows the decimal value for each drive configuration.  If your drive
is not listed in Appendix C, find your drive configuration in the table.  Then 
follow that row over to the decimal value.

          Table 4-10.  Configuration Bit Values in Decimal
            ÚÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄ¿ 
            ³ Command ³ Head  ³ Data  ³ Sector³ Decimal³
            ³ Complete³ Offset³ Strobe³ Value ³        ³
            ÃÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
            ³   OFF   ³  NO   ³  NO   ³  HARD ³    0   ³
            ³   OFF   ³  NO   ³  NO   ³  SOFT ³    1   ³
            ³   OFF   ³  NO   ³  YES  ³  HARD ³    2   ³
            ³   OFF   ³  NO   ³  YES  ³  SOFT ³    3   ³
            ³   OFF   ³  YES  ³  NO   ³  HARD ³    4   ³
            ³   OFF   ³  YES  ³  NO   ³  SOFT ³    5   ³
            ³   OFF   ³  YES  ³  YES  ³  HARD ³    6   ³
            ³   OFF   ³  YES  ³  YES  ³  SOFT ³    7   ³
            ³   ON    ³  NO   ³  NO   ³  HARD ³    8   ³
            ³   ON    ³  NO   ³  NO   ³  SOFT ³    9   ³
            ³   ON    ³  NO   ³  YES  ³  HARD ³   10   ³
            ³   ON    ³  NO   ³  YES  ³  SOFT ³   11   ³
            ³   ON    ³  YES  ³  NO   ³  HARD ³   12   ³
            ³   ON    ³  YES  ³  NO   ³  SOFT ³   13   ³
            ³   ON    ³  YES  ³  YES  ³  HARD ³   14   ³
            ³   ON    ³  YES  ³  YES  ³  SOFT ³   15   ³
            ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÙ

4.9.9   Split Code
------------------
This parameter allows the drive(s) defined by this parameter block to be split 
into two logical disk units (two each, if more than one drive is defined by 
this block).  The split codes are:

Code 0: No split.

Code 1: The cylinders are divided between the two logical drives.  A starting
        cylinder offset value specifies the first cylinder of the second
        logical drive.

Code 2: The drive's data heads are divided between the two logical drives.  A 
        starting head offset value specifies the first head of the second 
        logical drive.  If you select a head split code on a drive with both 
        fixed and removable media, the removable media may be configured as 
        logical unit number (LUN) 0 and the fixed media as LUN 1.

Code 3: Identical to Code 2 except the logical assignments for the physical 
        drives are reversed. Reverse head split codes also divide the drive by
        data heads, but assign the lower numbered heads to drive 1 and the 
        higher numbered heads to drive 0.

Use of the split option disables seek-ordering and overlapped seek processing 
in the MSCP Controller, which reduces performance, particularly when both 
logicals of a split physical drive are active.

If drive type 2 is selected, no splits are available.  

4.9.10   Cylinder Offset
------------------------
This parameter specifies the physical cylinder that is to be used as the first 
cylinder of the second logical drive.  This field has meaning only if a Split 
Code 1 is specified.   If a Split Code 0, 2, or 3 is selected, this parameter 
must be 0.

4.9.11   Starting Head Offset
-----------------------------
This parameter specifies the physical drive head that is to be used as the 
first head of the second logical drive.  This field has meaning only if a Split
Code 2 or 3 is specified.   The valid range is from 1 through 63.  If a Split
Code 0 or 1 is selected, this value must be 0.

4.9.12   Removable Media
------------------------
This parameter indicates whether the disk media is fixed or removable.  If you
are defining one logical/phsical drive, this parameter uses a 1-bit field with 
valid values of 0 and 1, where 0 indicates fixed media and 1 indicates 
removable media.

If you are defining a drive with a logical split, this parameter uses a 2-bit
field with a valid range from 0 through 3:

                 Definition                ³  Decimal Value
      ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
      LUN 0 and LUN 1 are both fixed.      ³  0
      LUN 0 is removable, LUN 1 is fixed.  ³  1
      LUN 0 is fixed, LUN 1 is removable.  ³  2
      LUN 0 and LUN 1 are both removable.  ³  3
     
4.9.13   Gap 0, 1, and 2 Parameters
-----------------------------------
These parameters specify the recording format for each sector on the drive. The
recording format allows gaps, as, for example, between header and data fields. 
These gaps are based on a formula intended to allow the drive time for 
read/write transitions while maximizing data capacity.

Enter the appropriate value for the type code 1 drive.  The values Emulex 
recommends for drives are calculated by using type code 2.

If you specified type code 2 for this drive, F.R.D. calculates these values
based on information provided by the drive.

4.9.14   Spiral Offset
----------------------
This parameter specifies the number of sectors by which sector 0 of a track is 
offset from sector 0 of the previous track.  Offsetting sector 0 from one track
to the next is a technique that is used to reduce latency when performing write
or read operations that cross a track boundary.  When the drive is formatted, 
sector 0 of a track is offset a certain number of sectors from the position of 
sector 0 on the previous track.  When this is done, spiral write and read 
operations are more efficient because the drive has time to switch heads before
encountering sector 0.

The valid range is from 0 through 31.  Use a spiral offset of 1 for all drives 
except Embedded Servo drive.  If you use an Embedded Servo drive (check the 
drive manual), use a spiral offset of 11.  If poor disk performance is noted, 
adjust the spiral offset value until maximum throughput is achieved.  Note: The
drive must be reformatted each time the spiral offset is changed.

4.10   Operation
----------------
There are no operational instructions.  The QD21 is ready for MSCP 
initialization as soon as its drives are formatted and tested.

4.10.1   Indicators
-------------------
There are three light emitting diodes (LEDs) on the QD21 PWB.  These LEDs are
used for both diagnostics and for normal operations.

If switch SW2-1 is OFF, the QD21 executes a preliminary test at the following
times:

  o  On power-up
  o  After a reset condition
  o  After a bus initialization
  o  After a write operation to the Initialization and Polling (IP) register
     (base address)

The self-test routine consists of two test sequences: preliminary and self-test
The preliminary test sequence exercises the 8031 microprocessor chip and the
Disk Formatter chip.  When the QD21 successfully completes the preliminary 
test, LED3 illuminates indicating that the QD21 is waiting for the MSCP
initialization sequence.

During the MSCP initialization sequence, initiated by host software control, 
the QD21 executes a self-test that exercises the buffer controller chip, the 
Host Adapter Controller (HAC) chip and its associated circuitry, the on-board 
RAM, and the control memory PROM.  If the QD21 passes this sequence of its 
self-test successfully, all the LED indicators on the edge of the QD21 are
OFF.

If a fatal error is detected either during self-test or while the system is 
running, all three of the edge-mounted LED indicators are ON (illuminated).  If
the QD21 fails to pass its power-up self-tests, you can select a special 
diagnostic mode (switch SW2-1 ON) which causes the LED indicators to display an
error code.  See Self-Test Error Reporting, in Section 5, TROUBLESHOOTING.

During normal operation, LED1 and LED2 flicker occasionally.  These LEDs are 
used to indicate LSI-11 bus activity and ESDI disk drive activity
respectively.

                      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                      ³ Section 5  TROUBLESHOOTING ³
                      ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

5.1   Overview
--------------
This section describes the several diagnostic features with which the QD21 
Disk Controller is equipped, and outlines fault isolation procedures that use 
these diagnostic features.

      Subsection ³          Title
      ÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
         5.2     ³ Service
         5.3     ³ Fault Isolation Procedure
         5.4     ³ Power-Up Self-Diagnostics
         5.5     ³ Fatal Error Codes

5.2   Service
-------------
Your Emulex QD21 Disk Controller was designed to give years of trouble-free 
service, and it was thoroughly tested before leaving the factory.

Should one of the fault isolation procedures indicate that the QD21 is not 
working properly, the product must be returned to the factory or to one of 
Emulex's authorized repair centers for service.  Emulex products are not 
designed to be repaired in the field.

Before returning the product to Emulex, whether the product is under warranty 
or not, you must contact the factory or the factory's representative for 
instructions and a Return Materials Authorization (RMA) number.

Do not return a component to EMULEX without authorization. A component returned
for service without an authorization will be returned to the owner at the
owner's expense.

In the continental United States, Alaska, and Hawaii contact:

      Emulex Technical Support
      3545 Harbor Boulevard
      Costa Mesa, CA 92626
      (714)662-5600  TWX 910-595-2521
      Outside California: (800) 852-7112
      
After 5 p.m. Pacific Time, call (800) 638-7243.  When answered, you will be 
prompted to key in 37115, followed by a # symbol, then a message.

Outside the United States, contact the distributor from whom the subsystem was 
initially purchased.

To help you efficiently, Emulex or its representative requires certain 
information about the product and the environment in which it is installed.
During installation, a record of the switch setting should have been made on 
the Configuration Reference Sheet.  This sheet is contained in the Installation
Section, Figure 4-1.

After you have contacted Emulex and received an RMA, package the component 
(preferably using the original packing material) and send the component postage
paid to the address given you by the Emulex representative.  The sender must
also insure the package.

5.3   Fault Isolation Procedure
-------------------------------
This fault isolation procedure is provided in flow chart format.  The procedure
is based on the self-diagnostics incorporated into the QD21.  The procedure 
is designed to be used if the product's self-diagnostic fails or if many errors
are flagged by the subsystem during normal operation.  If neither of these 
events happens, it is not necessary to follow these procedures.

The Fault Isolation Chart is shown in Figure 5-1. The chart symbols are defined
in Table 5-1.

              Table 5-1.  Flow Chart Symbol Definitions
              ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
     ÉÍÍÍÍÍÍÍÍÍÍ»
     º          º  START POINT, ENDING POINT
     ÈÍÍÍÍÍÍÍÍÍÍ¼
           /\
         /    \
       /        \
     /            \  DECISION, GO AHEAD ACCORDING WITH YES OR NO
     \            /
       \        /
         \    /
           \/
        ÚÄÄÄÄÄ¿
        ³     ³  CONNECTOR, GO TO SAME-NUMBERED SYMBOL
        ÀÄ¿ ÚÄÙ
          ÀÄÙ
      ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
      ³              ³  PROCESS
      ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ




      ÉÍÍÍÍÍÍÍÍÍÍ»
      º   START  º
      ÈÍÍÍÍÑÍÍÍÍÍ¼
           ³                  ÚÄÄÄÄÄ¿
  ÚÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄ¿        ³  1  ³
  ³   POWER UP QD21  ³        ÀÄ¿ ÚÄÙ
  ³DO NOT BOOT SYSTEM³          ÀÂÙ
  ÀÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÙ           ³
           ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
      ÚÄÄÄÄÁÄÄÄ¿
      ³READ SA ³
      ³REGISTER³
      ÀÄÄÄÄÂÄÄÄÙ
           ³
           /\
         / SA \              ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
       /REGISTER\            ³FATAL HARDWARE ERROR, RESEAT CONTROLLER³
     /IS 4400 OR  \  NO      ³OR MOVE IT TO ANOTHER BACKPLANE SLOT.  ³
     \    5400    /ÄÄÄÄÄÄÄÄÄÄ´CHECK CONTROLLER SWITCHES FOR CORRECT  ³
       \        /            ³CSR SELECTION. ENSURE YOU ARE ACCESSING³
         \    /              ³I/O PAGE ON 22-BIT SYSTEMS.            ³
           \/                ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
           ³YES
           ³
   ÚÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄ¿
   ³  UPLOAD F.R.D.  ³
   ³    TO MEMORY    ³
   ³SEE SECTION 4.7.3³
   ÀÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÙ
           ³
           /\
         /    \
       /EXAMINE \
     /   THE SA   \  NO      ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
     \REGISTER, IS/ÄÄÄÄÄÄÄÄÄÄ¶SUCCESSFUL F.R.D. LOADº
       \ BIT 15 /            ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ¼
         \SET?/
           \/
           ³YES
           ³
           /\               ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
         /    \             ³FATAL F.R.D. DMA TO MEMORY³  ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
       /        \           ³ON MICROVAX II, CHHECK TO ³  ³CALL EMULEX     ³
     /   SA BITS  \  YES    ³ENSURE YOU HAVE ENABLED   ³  ³CUSTOMER SERVICE³
     \ 07:00=121? /ÄÄÄÄÄÄÄÄÄ´MEMORY MAP, SEE SECTION   ÃÄÄ´IF RETRY IS     ³
       \        /           ³4.7.3                     ³  ³UNSUCCESSFUL    ³
         \    /             ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ  ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
           \/
           ³NO
           ³
           /\
         / SA \
       /  BITS  \           ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
     /  07:00=?   \  NO     ³CALL EMULEX     ³
     \SEE SECTION /ÄÄÄÄÄÄÄÄÄ´CUSTOMER SERVICE³
       \  5.5   /           ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
         \    /
           \/
           ³YES
           ³
  ÚÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄ¿
  ³DETERMINE FAULT AND³
  ³ATTEMPT TO CORRECT ³
  ÀÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÙ
           ³
        ÚÄÄÁÄÄ¿
        ³  1  ³
        ÀÄ¿ ÚÄÙ
          ÀÄÙ

                Figure 5-1.  Fault Isolation Chart
                ==================================

5.4   Power-Up Self-Diagnostic
------------------------------
QD21 executes an extensive self-diagnostic to ensure that the disk 
controller is in good working order.  The self-diagnostic is divided into 
several parts.  Table 5-2 lists the tests in the order in which they are 
performed. 

The first two tests are executed immediately after power-up, a reset, a bus 
INIT, or a write to the IP register (base address).  The other tests are 
executed as the controller interacts with the MSCP initialization routine.  If 
the QD21 fails any of the tests, it posts an MSCP fatal error code in the 
low-byte of the SA register (base address plus 2) and turns on three LEDs which
are located on the outside edge of the PWB.  The MSCP fatal error codes used by
the QD21 are listed in Table 5-3.  Note that some fatal errors may not allow
access to the SA register from the console.

To help determine the location of the problem, the operator can select a 
special diagnostic mode that causes the LEDs to display an error code.  To 
enable this diagnostic mode, place the CPU halt switch in the ON position and 
set QD21 switch SW2-1 ON (1).  After setting SW2-1 ON, the host computer must
be powered down or QD21 switch SW1-1 must be toggled (turned ON and then OFF)
to cause the QD21 to again perform its self-test.

Upon encountering an error, the host microprocessor halts and the LEDs display 
an error code.  The error codes are listed and described in Table 5-2.

If the QD21 completes the diagnostic mode without errors, all three LEDs are 
OFF.  Set switch SW2-1 in the OFF position and reset the QD21 controller 
before using.

                        Table 5-2.  LED Error Codes
       ÚÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
       ³   LED   ³                                                  ³
       ³ 3  2  1 ³        Error Description                         ³
       ÃÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
       ³ 0  0  0 ³ Self-Diagnostic complete without errors          ³
       ³ 0  0  1 ³ CPU Chip Test failed                             ³
       ³ 0  1  0 ³ Formatter Chip Test failed                       ³
       ³ 1  0  0 ³ Controller idle, waiting for initialization      ³
       ³ 0  1  1 ³ Buffer Controller or External Memory Test failed ³
       ³ 1  0  1 ³ HAC Test failed                                  ³
       ³ 1  1  0 ³ Emulation PROM Checksum Test failed              ³
       ÀÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

5.5   Fatal Error Codes
-----------------------
If the QD21 detects a fatal error anytime during operation, all three LEDs 
are illuminated and an error code is posted in the low byte of the SA register 
(base address plus 2).  Table 5-3 lists the MSCP fatal error codes used by the 
QD21.

           Table 5-3.  MSCP Fatal Error Codes Used by the QD21
       ÚÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿  
       ³Octal³ Hex ³ Description                                  ³
       ³Code ³ Code³                                              ³
       ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
       ³  0  ³  0  ³ No information in message packet.            ³
       ³     ³     ³                                              ³
       ³  1  ³  1  ³ Possible parity or timeout error when the    ³
       ³     ³     ³ QD21 attempted to read data from a message   ³
       ³     ³     ³ packet.                                      ³
       ³     ³     ³                                              ³
       ³  2  ³  2  ³ Possible parity or timeout error when the    ³
       ³     ³     ³ QD21 attempted to write data to a message    ³
       ³     ³     ³ packet.                                      ³
       ³     ³     ³                                              ³
       ³  4  ³  4  ³ QD21 diagnostic self-test indicated a        ³
       ³     ³     ³ controller RAM error.                        ³
       ³     ³     ³                                              ³
       ³  5  ³  5  ³ QD21 diagnostic self-test indicated a        ³
       ³     ³     ³ firmware checksum error.                     ³
       ³     ³     ³                                              ³
       ³  6  ³  6  ³ Possible parity or timeout error when the    ³
       ³     ³     ³ QD21 attempted to read an envelope address   ³
       ³     ³     ³ from a command ring.                         ³
       ³     ³     ³                                              ³
       ³  7  ³  7  ³ Possible parity or timeout error when the    ³
       ³     ³     ³ QD21 attempted to write an envelope          ³
       ³     ³     ³ address to a command ring.                   ³
       ³     ³     ³                                              ³
       ³ 11  ³  9  ³ Host did not communicate with QD21 within    ³
       ³     ³     ³ the time frame established while bringing    ³
       ³     ³     ³ the controller online.                       ³
       ³     ³     ³                                              ³
       ³ 12  ³  A  ³ Operating system sent more commands to the   ³
       ³     ³     ³ QD21 than the controller can accept.         ³
       ³     ³     ³                                              ³
       ³ 13  ³  B  ³ Controller unable to perform DMA transfer    ³
       ³     ³     ³ operation correctly.                         ³
       ³     ³     ³                                              ³
       ³ 14  ³  C  ³ QD21 diagnostic self-test indicated          ³
       ³     ³     ³ controller fatal error.                      ³
       ³     ³     ³                                              ³
       ³ 16  ³  E  ³ The MSCP connection identifier is invalid.   ³
       ³     ³     ³                                              ³
       ³ 23  ³ 13  ³ An error occurred during the MSCP            ³
       ³     ³     ³ initialization sequence.                     ³
       ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

Additional fatal error messages may appear.  These error codes are listed in 
Table 5-4.

                      Table 5-4.  Fatal Error Codes
             ÚÄÄÄÄÄÂÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
             ³Octal³Hex  ³ Description                   ³
             ³Code ³Code ³                               ³
             ÃÄÄÄÄÄÅÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
             ³ 004 ³  04 ³ RAM error                     ³
             ³     ³     ³                               ³
             ³ 005 ³  05 ³ Firmware checksum error       ³
             ³     ³     ³                               ³
             ³ 014 ³  0C ³ Fatal error during self-test  ³
             ³     ³     ³                               ³
             ³ 111 ³  49 ³ Autoboot timeout              ³
             ³     ³     ³                               ³
             ³ 121 ³  51 ³ F.R.D. load to memory failed  ³
             ÀÄÄÄÄÄÁÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

              ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
              ³ Section 6  DEVICE REGISTERS AND PROGRAMMING ³
              ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

6.1   Overview
--------------
This section contains an overview of the QD21 device registers that are 
accessible to the LSI-11 bus and that are used to monitor and control the 
QD21 Disk Controller.  The registers are functionally compatible with DEC
implementations of MSCP controllers.

The following table outlines the contents of this section.

      Subsection³         Title
      ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
         6.2    ³ Overview of MSCP Subsystem
         6.3    ³ Programming
         6.4    ³ Registers
         6.5    ³ Bootstrap Command


6.2   Overview of MSCP Subsystem
--------------------------------
Mass Storage Control Protocol (MSCP) is the protocol used by a family of mass 
storage controllers and devices designed and built by Digital Equipment 
Corporation.  MSCP allows a host system to be connected to subsystems with a 
variety of capacities and geometries. This flexibility is possible because MSCP
defines data locations in terms of sequential, logical blocks, not in terms of 
a physical description of the data's location (i.e., cylinder, track, and 
sector). This scheme gives the MSCP subsystem the responsibility for converting
MSCP logical block numbers into physical addresses that the peripheral device 
can understand.

This technique has several implications.  First, the MSCP subsystem must have 
detailed knowledge of the peripheral's capacity, geometry, and status.  Second,
the ability to make the translation between logical and physical addresses 
implies considerable intelligence on the part of the subsystem.  Finally, the 
host is relieved of responsibility for error detection and correction because 
its knowledge of the media is insufficient to allow error control to be done
efficiently.

There are several advantages to this type of architecture.  First, it provides 
the host with an "error-free" media.  Second, it provides for exceptional
operating system software portability because, with the exception of capacity, 
the characteristics of all MSCP subsystems are the same from the operating 
system's point of view.

In terms of implementation, this protocol requires a high degree of 
intelligence on the part of the subsystem.  Essentially, this intelligence is a
process that runs on a microprocessor and is referred to as an MSCP controller.
The MSCP controller has all of the responsibilities outlined above.

The host computer runs corresponding software processes which take calls from 
the operating system, convert them into MSCP commands, and cause the resulting 
command to be transferred to the MSCP controller.

In summary, an MSCP subsystem is characterized by an intelligent controller 
that provides the host with the view of a perfect media.  It is further
characterized by host independence from a specific bus, controller, or device 
type.

For more information about MSCP subsystems, see subsections 3.2, 3.3, and 3.4.

6.3   Programming
-----------------
A complete description of MSCP commands and the corresponding status responses 
which the QD21 Disk Controller posts is beyond the scope of this manual.  

6.3.1   MSCP Command Support
----------------------------
No currently available MSCP Controller supports the entire range of MSCP 
commands. The following subsections describe the extent of MSCP command support
by the QD21.

6.3.1.1   Minimal Disk Subset
-----------------------------
The QD21 Disk Controller supports the entire minimal disk subset of MSCP 
commands.

6.3.1.2   Diagnostic and Utility Protocol (DUP)
-----------------------------------------------
The QD21 Disk Controller does not support any of the DUP commands or 
maintenance read/write commands.  Therefore, the QD21 is not compatible with 
DEC diagnostics that use the MSCP DUP commands.

6.4   Registers
---------------
During normal operation, the QD21 Disk Controller is controlled and monitored
using the command and status packets that are exchanged by the Class Driver 
(host) and the MSCP Controller.  The QD21 has two 16-bit registers in the 
LSI-11 Bus I/O page that are used primarily to initialize the subsystem. During
normal operation, the registers are used only to initiate polling or to reset
the subsystem.  These registers are always read as words.  The register pair 
begins on a longword boundary. Table 6-1 lists the octal and hexadecimal values
for the Initialization and Polling (IP) register (base address) and the Status 
and Address (SA) register (base address plus 2) supported by the QD21.

The IP register (base address) has two functions as detailed below:

  o  When written with any value, it causes a hard initialization of the MSCP
     Controller.

  o  When read while the port is operating, it causes the controller to 
     initiate polling.

The SA register (base address plus 2) has four functions as listed below:

  o  When read by the host during initialization, it communicates data and 
     error information relating to the initialization process.

  o  When written by the host during initialization, it communicates certain
     host-specific parameters to the port.

  o  When read by the host during normal operation, it communicates status
     information including port and controller-detected fatal errors.

  o  When zeroed by the host during either initialization or normal operation,
     it signals the port that the host has successfully completed a bus adapter
     purge in response to a port-initiated purge request.

                 Table 6-1.  QD21 IP and SA Registers
                     ÚÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄ¿
                     ³Register³ Octal  ³Hexadecimal³
                     ÃÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄ´
                     ³   IP   ³ 772150 ³ 20001468  ³
                     ³   SA   ³ 772152 ³ 2000146A  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 772154 ³ 2000146C  ³
                     ³   SA   ³ 772156 ³ 2000146E  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760334 ³ 200000DC  ³
                     ³   SA   ³ 760336 ³ 200000DE  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760340 ³ 200000E0  ³
                     ³   SA   ³ 760342 ³ 200000E2  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760344 ³ 200000E4  ³
                     ³   SA   ³ 760346 ³ 200000E6  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760350 ³ 200000E8  ³
                     ³   SA   ³ 760352 ³ 200000EA  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760354 ³ 200000EC  ³
                     ³   SA   ³ 760356 ³ 200000EE  ³
                     ³        ³        ³           ³
                     ³   IP   ³ 760360 ³ 200000F0  ³
                     ³   SA   ³ 760362 ³ 200000F2  ³
                     ÀÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÙ
                
6.5   Bootstrap Command
-----------------------
To allow the system to be easily bootstrapped from peripherals attached to the 
QD21 Disk Controller, Emulex has incorporated a  Bootstrap Command into the
controller.  This feature is not part of the standard MSCP command set nor is 
it supported on the MicroVAX or on systems using an 11/73B CPU module.

The Bootstrap Command can be issued from the console after the system is 
powered up, or it may be incorporated into a firmware routine that is located 
in a Bootstrap ROM.  (The ROM would not be located on the QD21 PWB, but on 
some other module in the system.)  The Bootstrap Command causes the QD21 to 
load the first logical block from the selected peripheral into host memory 
starting at location 00000.

To issue the Bootstrap Command to the QD21:

  1. Initialize the QD21 by writing any value into the IP register (base 
     address).  The QD21 performs self-test and begins the initialization 
     dialog.

      Register  ³  Octal
      ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      IP: Write ³ 000001

  2. The QD21 indicates that initialization step 1 has begun by setting bit 
     11 in the SA register (base address plus 2).  The host must poll the 
     register for this value (no interrupt is generated).  Bit 8 should also be
     set.  If 22-bit addressing is enabled, bit 9 will be set.

      Register ³  Octal  ³Addressing
      ÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄ
      SA: Read ³ 0044000 ³  18-Bit
               ³ 005400  ³  22-Bit

  3. When the controller indicates that step 1 of the initialization dialog is
     begun, load the SA register (base address plus 2) with the "special
     initialization code:"

      Register  ³  Octal
      ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      SA: Write ³ 030003

  4. The controller acknowledges the initialization code with 00400.

      Register ³  Octal
      ÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      SA: Read ³ 000400

  5. Load the SA register (base address plus 2) with 04000n(8) or 400n(16), 
     where n is the MSCP logical unit number of the unit to bootstrap from.  In
     this example, the unit is 0.

      Register  ³  Octal
      ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ
      SA: Write ³ 040000

  6. At the console emulator prompt, enter P to begin:

      @P


                     ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                     ³ Section 7  FUNCTIONAL DESCRIPTION ³
                     ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

7.1   Overview
--------------
This section contains a description of the QD21 Disk Controller's 
architecture.

7.2   QD21 Disk Controller Architecture
-----------------------------------------
The QD21 is a microprocessor-based emulating disk controller that is 
contained on a single dual-wide PCBA.  The QD21's major functional blocks are
shown in Figure 7-1.  The disk controller is organized around the eight-bit 
8031 microprocessor.  The board has an eight-bit internal data bus with 16-bit 
addressing capability.  The Host Adapter Controller, the Formatter Controller,
and the Buffer Controller are addressed as memory (memory-mapped I/O).

The 8031's primary task is to decode and implement commands from the host.  At 
command completion, the microprocessor is also responsible for generating 
status and transmitting it to the host.  A large part of the microprocessor's
job while performing those duties involves setting up the Host Adapter 
Controller and the Buffer Controller for the large data transfers that are
their specialties.

The QD21 uses a 27256 erasable programmable read-only memory (EPROM), which 
contains the control program, and 16K bytes of random access memory (RAM), 
which is used for data buffering and working storage.

The LSI-11 bus interface contains 22 lines.  Sixteen of the lines are 
multiplexed for both address and data; six are used for only address.  The Host
Adapter Controller is used for programmed I/O, CPU interrupts, and DMA data
transfers.  The microprocessor responds to all programmed I/O and carries out 
the I/O functions required for the addressed disk controller register. The Host
Adapter Controller has automatic LSI-11 bus address generation capability that,
in conjunction with a byte counter, allows the interface to conduct LSI-11
bus DMA transfers without direct microprocessor intervention after the 
interface is set up for a transfer.  This automatic DMA capability is used with
the QD21 Buffer Controller to transfer large blocks of data directly between 
host memory and the QD21's RAM.

The Buffer Controller is implemented on a single chip.  This multi-channel DMA 
is responsible for moving large blocks of data between the 16K RAM buffer and 
the ESDI interface, and between the LSI-11 bus interface and the 16K RAM 
buffer.  After being set up for an operation by the microprocessor, either 
interface requests DMA service from the Buffer Controller by driving an
individual request signal active.  The transfer then proceeds without direct 
intervention by the microprocessor.  This allows high-speed data transfers to
occur while the microprocessor is focused on other processes.



                       ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                       ³ Section 8  INTERFACES ³
                       ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

8.1   Overview
--------------
This section describes the interfaces that the QD21 Disk Controller 
incorporates.  It includes information on the QD21 implementation of ESDI
interface electrical and mechanical requirements.  Excluding this overview, the
section is divided into the following subsections.

      Subsection³      Title
      ÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
          8.2   ³ QD21 LSI-11 Bus Interface
          8.3   ³ QD21 ESDI Drive Interface

8.2   LSI-11 Bus Interface
--------------------------
The LSI-11 bus between the CPU and the QD21 Disk Controller contains 42 
bidirectional signal lines and two unidirectional signal lines on connectors A 
and B, and two unidirectional signal lines on connector C. LSI-11 bus interface
pin assignments are listed and described in Table 8-1.  These signal lines 
provide the means by which the CPU and the QD21 Disk Controller communicate
with each other.

The LSI-11 bus interface is used for programmed I/O, CPU interrupts, and DMA 
data transfer operations.  Addresses, data, and control information are sent 
along these signal lines, some of which contain time-multiplexed information. 
The LSI-11 bus interface lines are grouped in the following categories:

  o  Twenty-two Data/Address Lines <BDAL00:BDAL21> The four Data/Address lines
     which carry the most significant bits (MSB) are lines BDAL21:BDAL18. They
     are used for addressing only and do not carry data. Lines BDAL17 and 
     BDAL16 reflect the parity status of the 16-bit data word during a Write or
     Read Data Transfer operation via the LSI-11 bus cycle.

  o  Six Data Transfer Control Lines BBS7, BDIN, BDOUT, BRPLY, BSYNC, and BWTBT

  o  Six Direct Memory Access (DMA) Control Lines BDMR, BSACK, BDMGI, and BDMGO
     (the last two are on both connectors A and C).

  o  Seven Interrupt Control Lines BEVNT, BIAKI, BIAKO, BIRQ4, BIRQ5, BIRQ6, 
     and BIRQ7.

  o  Five System Control Lines BDCOK, BHALT, BINIT, BPOK, and BREF.

              Table 8-1. LSI-11 Bus Interface Pin Assignments
           ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
           ³    Connector A Signal   ³    Connector B Signal   ³
           ÃÄÄÄÄÄÄÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÄÄÄ´
           ³Component ³   ³ Solder   ³Component ³   ³ Solder   ³
           ³   Side   ³Pin³  Side    ³   Side   ³Pin³ Side     ³
           ÃÄÄÄÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÄÄÄ´
           ³ BIRQ5    ³ A ³ +5V      ³  BDCOK   ³ A ³ +5V      ³
           ³ BIRQ6    ³ B ³ BPOK     ³          ³ B ³          ³
           ³ BDAL16   ³ C ³ 0V (GND) ³  BDAL18  ³ C ³ 0V (GND) ³
           ³ BDAL17   ³ D ³ BDAL19   ³          ³ D ³          ³
           ³          ³ E ³ BDOUT    ³  BDAL20  ³ E ³ BDAL02   ³
           ³          ³ F ³ BRPLY    ³  BDAL21  ³ F ³ BDAL03   ³
           ³          ³ H ³ BDIN     ³          ³ H ³ BDAL04   ³
           ³ 0V (GND) ³ J ³ BSYNC    ³ 0V (GND) ³ J ³ BDAL05   ³
           ³          ³ K ³ BWTBT    ³          ³ K ³ BDAL06   ³
           ³          ³ L ³ BIRQ4    ³          ³ L ³ BDAL07   ³
           ³ 0V (GND) ³ M ³ BIAKI    ³ 0V (GND) ³ M ³ BDAL08   ³
           ³ BDMR     ³ N ³ BIAKO    ³  BSACK   ³ N ³ BDAL09   ³
           ³ BHALT    ³ P ³ BBS7     ³  BIRQ7   ³ P ³ BDAL10   ³
           ³ BREF     ³ R ³ BDMGI    ³  BEVNT   ³ R ³ BDAL11   ³
           ³          ³ S ³ BDMGO    ³          ³ S ³ BDAL12   ³
           ³ 0V (GND) ³ T ³ BINIT    ³ 0V (GND) ³ T ³ BDAL13   ³
           ³          ³ U ³ BDAL00   ³          ³ U ³ BDAL14   ³
           ³          ³ V ³ BDAL01   ³          ³ V ³ BDAL15   ³
           ÃÄÄÄÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄ´
           ³    Connector C Signal   ³    Connector D Signal   ³
           ÃÄÄÄÄÄÄÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÂÄÄÄÂÄÄÄÄÄÄÄÄÄÄ´
           ³ Component³   ³ Solder   ³Component ³   ³ Solder   ³
           ³   Side   ³Pin³  Side    ³  Side    ³Pin³  Side    ³
           ÃÄÄÄÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÅÄÄÄÄÄÄÄÄÄÄ´
           ³          ³ A ³ +5V      ³          ³ A ³ +5V      ³
           ³          ³ B ³          ³          ³ B ³          ³
           ³          ³ C ³ 0V (GND) ³          ³ C ³ 0V (GND) ³
           ³          ³ D ³          ³          ³ D ³          ³
           ³          ³ E ³          ³          ³ E ³          ³
           ³          ³ F ³          ³          ³ F ³          ³
           ³          ³ H ³          ³          ³ H ³          ³
           ³ 0V (GND) ³ J ³          ³ 0V (GND) ³ J ³          ³
           ³          ³ K ³          ³          ³ K ³          ³
           ³          ³ L ³          ³          ³ L ³          ³
           ³ 0V (GND) ³ M ³ BIAKI    ³ 0V (GND) ³ M ³          ³
           ³          ³ N ³ BIAKO    ³          ³ N ³          ³
           ³          ³ P ³          ³          ³ P ³          ³
           ³          ³ R ³ BDMGI    ³          ³ R ³          ³
           ³          ³ S ³ BDMGO    ³          ³ S ³          ³
           ³ 0V (GND) ³ T ³          ³ 0V (GND) ³ T ³          ³
           ³          ³ U ³          ³          ³ U ³          ³
           ³          ³ V ³          ³          ³ V ³          ³
           ÃÄÄÄÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÁÄÄÄÁÄÄÄÄÄÄÄÄÄÄ´
           ³All signals, except BDCOK and BPOK, are low active ³
           ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

8.2.1   Interrupt Priority Level
--------------------------------
The QD21 is hard-wired to issue level 4 interrupt requests and monitor level 
5.  The level 4 request is necessary to allow compatibility with either an 
LSI-11 or LSI-11/2 CPU.

8.2.2   Register Address
------------------------
The QD21 Disk Controller has two registers visible to the LSI-11 bus.  Their 
addresses are determined by DIP switches SW2-3 through SW2-5. See Section 4 for
detailed address and switch setting information.

8.2.3   DMA Operations
----------------------
All DMA data transfer operations are performed under microprocessor control.  
When doing a Read or From Memory operation, a check is made for memory parity 
or nonexistent memory (NXM) errors; during Write operation a check is made for 
NXM errors.  If an error is detected, an MSCP status error is returned.

8.2.4   Scatter/Gather
----------------------
The QD21 Disk Controller supports the MicroVAX I I/O technique of scatter-
write operations and gather-read operations.

8.3   QD21 ESDI Disk Drive Interface
----------------------------------------
This subsection provides information on the QD21 implementation of the Enhanced
Small Device Interface (ESDI) interface.  The QD21 controller's disk interface
conforms to the ESDI Specification and supports the serial mode for magnetic
disk drives.  The QD21 does not use the drive's defect list.

The QD21 Controller interfaces with disk drives via a 34-pin control cable and 
a 20-pin data cable (for each disk drive). A 34-pin male connector at reference
designator J3 on the QD21 Controller plugs directly into the ESDI disk drive
control cable.  The QD21 Controller contains two 20-pin male connectors, one at
reference designator J1 and one at reference designator J2.

The QD21 Controller can integrate up to a maximum of two disk drives.  Either 
20-pin connector (reference designator J1 or J2) can plug directly into the 
data cable for the first disk drive.  If a second disk drive is configured, the
unused 20-pin connector is plugged into the data cable for that disk drive.

The pin/signal assignments for control signal interface between the QD21 
Controller and an ESDI disk drive are shown in Figure 8-1.

         CONTROLLER        CONTROL SIGNALS            DRIVE  
        ÉÍÍÍÍÍÍÍÍÍÍÍ» FLAT CABLE OR TWISTED PAIR ÉÍÍÍÍÍÍÍÍÍÍÍÍÍ»
        º           º      3 METERS MAXIMUM      º             º
        º      ÚÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ1Ä¿      º
        º      ³    ÇÄÄÄÄ - HEAD SELECT 2(3) ÄÄÄÄ¶2     ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ3Ä´      º
        º      ³    ÇÄÄÄÄ - HEAD SELECT 2(2) ÄÄÄÄ¶4     ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ5Ä´      º
        º      ³    ÇÄÄÄÄÄ - WRITE GATE ÄÄÄÄÄÄÄÄÄ¶6     ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ7Ä´      º
        º      ³    ÇÄÄÄ - CONFIG-STATUS DATA ÄÄÄ¶8     ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ9Ä´      º
        º      ³    ÇÄÄÄÄÄ Ä TRANSFER ACK ÄÄÄÄÄÄÄ¶10    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ11´      º
        º      ³    ÇÄÄÄÄÄÄ - ATTENTION ÄÄÄÄÄÄÄÄÄ¶12    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ13´      º
        º      ³    ÇÄÄÄÄÄÄ - HEAD SELECT 0 ÄÄÄÄÄ¶14    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ15´      º
        º      ³    ÇÄ - SECTOR/-ADDRESS MARK ÄÄÄ¶16    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ17´      º
        º      ³    ÇÄÄÄÄÄ - HEAD SELECT 2 ÄÄÄÄÄÄ¶18    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ19´      º
        º      ³    ÇÄÄÄÄÄÄÄÄ - INDEX ÄÄÄÄÄÄÄÄÄÄÄ¶20    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ21´      º
        º      ³    ÇÄÄÄÄÄÄÄ - READY ÄÄÄÄÄÄÄÄÄÄÄÄ¶22    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ23´      º
        º      ³    ÇÄÄÄÄÄÄÄ - TRANSFER REQ ÄÄÄÄÄ¶24    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ25´      º
        º      ³    ÇÄÄÄÄÄ Ä DRIVE SELECT 1 ÄÄÄÄÄ¶26    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ27´      º
        º      ³    ÇÄÄÄÄÄ - DRIVE SELECT 2 ÄÄÄÄÄ¶28    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ29´      º
        º      ³    ÇÄÄÄÄÄ - DRIVE SELECT 3 ÄÄÄÄÄ¶30    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ31´      º
        º      ³    ÇÄÄÄÄÄÄÄ - READ GATE ÄÄÄÄÄÄÄÄ¶32    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ33´      º
        º      ³    ÇÄÄÄÄÄÄ - COMMAND DATA ÄÄÄÄÄÄ¶34    ³      º
        º    ÄÄÁÄÄ  º                            º    ÄÄÁÄÄ    º
        º     ÄÄÄ   º                            º     ÄÄÄ     º
        ÈÍÍÍÍÍÍÍÍÍÍÍ¼                            ÈÍÍÍÍÍÍÍÍÍÍÍÍÍ¼

        Figure 8-1.  Control Pin/Signal Assignments at ESDI
                     Disk Drive Interface (Connector J1)
        ======================================================


         CONTROLLER          DATA SIGNALS             DRIVE 
        ÉÍÍÍÍÍÍÍÍÍÍÍ» FLAT CABLE OR TWISTED PAIR ÉÍÍÍÍÍÍÍÍÍÍÍÍÍ»
        º           º     3 METERS MAXIMUM       º             º
        º           Ç<Ä - DRIVE SELECTED ÄÄÄÄÄÄÄÄ¶1            º
        º         NCÇ<ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¶2            º
        º           Ç<Ä - COMMAND COMPLETE ÄÄÄÄÄÄ¶3            º
        º           ÇÄÄ - ADDRESS MARK ENABLE ÄÄ>¶4            º
        º         NCÇ< - RESERVED FOR STEP MODE Ä¶5            º
        º      ÚÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ6Ä¿      º
        º      ³    ÇÄÄÄÄÄ + WRITE CLOCK ÄÄÄÄÄÄÄ>¶7     ³      º
        º      ³    ÇÄÄÄÄÄ - WRITE CLOCK ÄÄÄÄÄÄÄ>¶8     ³      º
        º      ³  NCÇ< - RESERVED FOR STEP MODE Ä¶9     ³      º
        º      ³    Ç<Ä + READ/REFERENCE CLOCK ÄÄ¶10    ³      º
        º      ³    Ç<Ä - READ/REFERENCE CLOCK ÄÄ¶11    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ12´      º
        º      ³    ÇÄÄÄÄ + NRZ WRITE DATA ÄÄÄÄÄÄ¶13    ³      º
        º      ³    ÇÄÄÄÄ - NRZ WRITE DATA ÄÄÄÄÄÄ¶14    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ15´      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ16´      º
        º      ³    ÇÄÄÄÄÄÄ + NRZ READ DATA ÄÄÄÄÄ¶17    ³      º
        º      ³    ÇÄÄÄÄÄÄ - NRZ READ DATA ÄÄÄÄÄ¶18    ³      º
        º      ÃÄÄÄÄ×ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ×ÄÄÄÄ19´      º
        º      ³    ÇÄÄÄÄÄÄÄÄ - INDEX ÄÄÄÄÄÄÄÄÄÄÄ¶20    ³      º
        º      ³    º                            º      ³      º
        º    ÄÄÁÄÄ  º                            º    ÄÄÁÄÄ    º
        º     ÄÄÄ   º                            º     ÄÄÄ     º
        º      Ä    º                            º      Ä      º
        ÈÍÍÍÍÍÍÍÍÍÍÍ¼                            ÈÍÍÍÍÍÍÍÍÍÍÍÍÍ¼
         Figure 8-2.  Data Pin/Signal Assignments at ESDI
                      Disk Drive Interface (Connector J2 or J5)
         ======================================================

8.4   Front Panel Interface
---------------------------
The QD21 provides an interface that allows a remote control and status panel 
to be connected to the controller.  The interface allows write protect switches
for each ESDI drive to be connected, and it provides drivers for ready and 
write-protected status LEDs.

The interface is implemented by using a four-wall, right-angle header (3M part 
number 3591-5002) designated J3.  The header has 10 pins.  The function of each
pin is described in Table 8-2.  Figure 8-3 shows the pin-outs and a sample user
interface.

     Table 8-2.  Control and Status Interface Pin Function Description
ÚÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³Pin³         Function           ³                Description                ³
ÃÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
³ 1 ³ Ground                     ³ Controller Logic Ground                   ³
³   ³                            ³                                           ³
³ 2 ³ Not Connected              ³                                           ³
³   ³                            ³                                           ³
³ 3 ³ Disk 1 Write Protect Input ³ Ground this line to write protect disk 1  ³
³   ³                            ³                                           ³
³ 4 ³ Disk 1 Ready Status        ³ This line sinks 24 mA when disk 1 is ready³
³   ³                            ³                                           ³
³ 5 ³ Disk 0 Write Protect Input ³ Ground this line to write protect disk 0  ³
³   ³                            ³                                           ³
³ 6 ³ Disk 0 Ready Status        ³ This line sinks 24 mA when disk 0 is ready³
³   ³                            ³                                           ³
³ 7 ³ Disk 1 Write Protect Status³ This line sinks 24 mA when disk 1 is write³
³   ³                            ³ protected                                 ³
³   ³                            ³                                           ³
³ 8 ³ Not connected              ³                                           ³
³   ³                            ³                                           ³
³ 9 ³ Disk 0 Write Protect Status³ This line sinks 24 mA when disk 0 is write³
³   ³                            ³ protected                                 ³
³   ³                            ³                                           ³
³10 ³ +5 Vdc                     ³ This line provides 5 Vdc. This line is not³
³   ³                            ³ current protected.                        ³
ÀÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

                            +5V
                         10ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                             DISK0 RDY          ³
                          6ÄÄÄÄ´<ÃÄÄÄÄÄÄXXXXÄÄÄÄ´
                             DISK1 RDY          ³
                          4ÄÄÄÄ´<ÃÄÄÄÄÄÄXXXXÄÄÄÄ´
                             DISK0 WP           ³
                          9ÄÄÄÄ´<ÃÄÄÄÄÄÄXXXXÄÄÄÄ´
                             DISK1 WP           ³
                          7ÄÄÄÄ´<ÃÄÄÄÄÄÄXXXXÄÄÄÄÙ


                                WP DISK0
                                      / N.O.
                          5ÄÄÄÄÄÄÄÄo/  oÄÄÄÄÄÄÄÄ¿
                                                ³
                               WP DISK1         ³
                                      / N.O.    ³
                          3ÄÄÄÄÄÄÄÄo/  oÄÄÄÄÄÄÄÄ´
                                                ³
                          1ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
                           ³
                          \³/
 
             Figure 8-3.  Status and Control Interface
             =========================================



            ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
            ³ Appendix A  AUTOCONFIGURE, CSR AND VECTOR ADDRESSES ³
            ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

A.1   Overview
--------------
The following discussion presents the algorithm for assignment of floating 
addresses and vectors for all DEC operating systems.  Bus addresses are 
discussed in subsection 3.3.2.

A.2   Determining the CSR Address for Use With Autoconfigure
------------------------------------------------------------
The term Autoconfigure refers to a software utility that is run when the 
computer is bootstrapped.  This utility finds and identifies I/O devices in the
I/O page of system memory.

Some devices (like the DM11) have fixed addresses reserved for them.  
Autoconfigure detects their presence by simply testing their standard address 
for a response.  Specifically, the control/status register (CSR) address, which
is usually the first register of the block, is tested.

Addresses for those devices not assigned fixed numbers are selected from the 
floating CSR address space (760010-763776) of the Unibus input/output (I/O)
page.  This means that the presence or absence of floating devices will affect 
the assignment of addresses to other floating-address devices.  Similarly, many
devices have floating interrupt vector addresses.  According to the DEC 
standard, vectors must be assigned in a specific sequence and the presence of 
one type of device will affect the correct assignment of vectors for other
devices.

The CSR address for a floating-address device is selected according to the 
algorithm used during autoconfigure.  The algorithm is used in conjunction
with a Device Table, Table A-1.

Essentially, Autoconfigure checks each valid CSR address in the floating CSR 
address space for the presence of a device.  Autoconfigure expects any devices 
installed in that space to be in the order specified by the Device Table.  
Also, the utility expects an eight-byte block to be reserved for each device 
that is not installed in the system.  Each empty block tells Autoconfigure to
look at the next valid address for the next device on the list.

When a device is detected, a block of addresses is reserved for the device 
according to the number of registers it employs.  The utility then looks at the
next CSR for that device type.  If there is a device there, it is assumed to be
of the same type as the one before it and a block is reserved for that device.
If there is no response at the next address, that space is reserved to indicate
that there are no more devices of that type.  Then the utility checks the CSR 
address (at the appropriate boundary) for the next device in the table.

                         Table A-1.  SYSGEN Device Table
      ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄ¿
      ³     ³           ³Number of³ Octal ³    ³         ³Number of³ Octal ³
      ³Rank ³ Device    ³Registers³Modulus³Rank³ Device  ³Registers³Modulus³
      ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ´
      ³  1  ³ DJ11      ³    4    ³  10   ³ 17 ³ Reserved³  4      ³ 10    ³
      ³  2  ³ DH11      ³    8    ³  20   ³ 18 ³ RX11 *2 ³  4      ³ 10    ³
      ³  3  ³ DQ11      ³    4    ³  10   ³ 18 ³ RX211 *2³  4      ³ 10    ³
      ³  4  ³ DU11,DUV11³    4    ³  10   ³ 18 ³ RXV11 *2³  4      ³ 10    ³
      ³  5  ³ DUP11     ³    4    ³  10   ³ 18 ³ RXV21 *2³  4      ³ 10    ³
      ³  6  ³ LK11A     ³    4    ³  10   ³ 19 ³ DR11-W  ³  4      ³ 10    ³
      ³  7  ³ DMC11     ³    4    ³  10   ³ 20 ³ DR11-B*3³  4      ³ 10    ³
      ³  7  ³ DMR11     ³    4    ³  10   ³ 21 ³ DMP11   ³  4      ³ 10    ³
      ³  8  ³ DZ11 *1   ³    4    ³  10   ³ 22 ³ DPV11   ³  4      ³ 10    ³
      ³  8  ³ DZV11     ³    4    ³  10   ³ 23 ³ ISB11   ³  4      ³ 10    ³
      ³  8  ³ DZS11     ³    4    ³  10   ³ 24 ³ DMV11   ³  8      ³ 20    ³
      ³  8  ³ DZ32      ³    4    ³  10   ³ 25 ³ DEUNA *2³  4      ³ 10    ³
      ³  9  ³ KMC11     ³    4    ³  10   ³ 26 ³ UDA50 *2³  2      ³  4    ³
      ³ 10  ³ LPP11     ³    4    ³  10   ³ 27 ³ DMF32   ³ 16      ³ 40    ³
      ³ 11  ³ VMV21     ³    4    ³  10   ³ 28 ³ KMS11   ³  6      ³ 20    ³
      ³ 12  ³ VMV31     ³    8    ³  20   ³ 29 ³ VS100   ³  8      ³ 20    ³
      ³ 13  ³ DWR70     ³    4    ³  10   ³ 30 ³ TU81    ³  2      ³  4    ³
      ³ 14  ³ RL11 *2   ³    4    ³  10   ³ 31 ³ KMV11   ³  8      ³ 20    ³
      ³ 14  ³ RLV11 *2  ³    4    ³  10   ³ 32 ³ DHV11   ³  8      ³ 20    ³
      ³ 15  ³ LPA11-K *2³    8    ³  20   ³ 33 ³ DMZ32   ³ 16      ³ 40    ³
      ³ 16  ³ KW11-C    ³    4    ³  10   ³ 34 ³ CP132   ³ 16      ³ 40    ³
      ÀÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÙ
        *1  DZ11-E and DZ11-F are treated as two DZ11s.
        *2  The first device of this type has a fixed address.  Any
            extra devices have a floating address.
        *3  The first two devices of this type have a fixed address.
            Any extra devices have a floating address.


In summary, there are four rules that pertain to the assignment of device 
addresses in floating address space:

1.  Devices with floating addresses must be attached in the order in which they
    are listed in the Device Table, Table A-1.

2.  The CSR address for a given device type is assigned on word boundaries 
    according to the number of UNIBUS-accessible registers that the device has.
    The following table relates the number of device registers to possible word
    boundaries.

                 ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                 ³Device Registers³     Possible Boundaries     ³
                 ÃÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
                 ³    1           ³ Any Word                    ³
                 ³    2           ³ XXXXX0, XXXXX4              ³
                 ³    3,4         ³ XXXXX0                      ³
                 ³    5,6,7,8     ³ XXXX00,XXXX20,XXXX40,XXXX60 ³
                 ³    9 thru 16   ³ XXXX00,XXXX40               ³
                 ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
 
    The Autoconfigure utility inspects for a given device type only at one of 
    the possible boundaries for that device. That is, the utility does not look
    for a DMF32 (16 registers) at an address that ends in 20.

3.  An 8-byte gap must follow the register block of any installed device to 
    indicate that there are no more of that type of device. This gap must start
    on the proper CSR address boundary for that type of device.

4.  An 8-byte gap must be reserved in floating address space for each device 
    type that is not installed in the current system. The gap must start on the
    proper word boundary for the type of device the gap represents.  That is, a
    single DJ11 installed at 760010 would be followed by a gap starting at 
    760020 to show a change of device types.  A gap to show that there are none
    of the next device on the list, a DH11, would begin at 760040, the next 
    legal boundary for a DH11-type device.

A.3   Determining the Vector Address for Use With Autoconfigure
---------------------------------------------------------------
There is a floating vector address convention that is used for communications 
and other devices which interface with the Unibus.  These vector addresses are
assigned in order starting at 300 and proceeding upwards to 777.  Table A-2 
shows the assignment sequence.  For a given system configuration, the device 
with the highest floating vector rank would be assigned to vector address 300.
Additional devices of the same type would be assigned subsequent vector 
addresses according to the number of vectors required per device, and according
to the starting boundary assigned to that device type.

             Table A-2.Priority Ranking for Floating Vector Addresses
                       (starting at 3008 and proceeding upwards)
                     ÚÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄ¿
                     ³    ³                 ³Number ³       ³
                     ³    ³                 ³  of   ³ Octal ³
                     ³Rank³Device           ³Vectors³Modulus³
                     ÃÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄ´
                     ³ 1  ³DC11             ³   2   ³  10   ³
                     ³ 1  ³TU58             ³   2   ³  10   ³
                     ³ 2  ³KL11 *1          ³   2   ³  10   ³
                     ³ 2  ³DL11-A *1        ³   2   ³  10   ³
                     ³ 2  ³DL11-B *1        ³   2   ³  10   ³
                     ³ 2  ³DLV11-J *1       ³   8   ³  40   ³
                     ³ 2  ³DLV11,DLV11-F *1 ³   2   ³  10   ³
                     ³ 3  ³DP11             ³   2   ³  10   ³
                     ³ 4  ³DM11-A           ³   2   ³  10   ³
                     ³ 5  ³DN11             ³   1   ³   4   ³
                     ³ 6  ³DM11-BB/BA       ³   1   ³   4   ³
                     ³ 7  ³DH11 modem cntrl ³   1   ³   4   ³
                     ³ 8  ³DR11-A, DRV11-B  ³   2   ³  10   ³
                     ³ 9  ³DR11-C, DRV11    ³   2   ³  10   ³
                     ³10  ³PA611(readr/pnch)³   4   ³  20   ³
                     ³11  ³LPD11            ³   2   ³  10   ³
                     ³12  ³DT07             ³   2   ³  10   ³
                     ³13  ³DX11             ³   2   ³  10   ³
                     ³14  ³DL11-C to DLV11-F³   2   ³  10   ³
                     ³15  ³DJ11             ³   2   ³  10   ³
                     ³16  ³DH11             ³   2   ³  10   ³
                     ³17  ³VT40             ³   4   ³  20   ³
                     ³17  ³VSV11            ³   4   ³  10   ³
                     ³18  ³LPS11            ³   6   ³  40   ³
                     ³19  ³DQ11             ³   2   ³  10   ³
                     ³20  ³KW11-W, KWV11    ³   2   ³  10   ³
                     ³21  ³DU11, DUV11      ³   2   ³  10   ³
                     ³22  ³DUP11            ³   2   ³  10   ³
                     ³23  ³DV11 modem cntrl ³   3   ³  20   ³
                     ³24  ³LK11-A           ³   2   ³  10   ³
                     ³25  ³DWUN             ³   2   ³  10   ³
                     ³26  ³DMC11            ³   2   ³  10   ³
                     ³26  ³DMR11            ³   2   ³  10   ³
                     ³27  ³DZ11/DZS11/DZV11 ³   2   ³  10   ³
                     ³27  ³DZ32             ³   2   ³  10   ³
                     ³28  ³KMC11            ³   2   ³  10   ³
                     ³29  ³LPP11            ³   2   ³  10   ³
                     ³30  ³VMV21            ³   2   ³  10   ³
                     ³31  ³VMV31            ³   2   ³  10   ³
                     ³32  ³VTV01            ³   2   ³  10   ³
                     ³33  ³DWR70            ³   2   ³  10   ³
                     ³34  ³RL11/RLV11 *2    ³   1   ³   4   ³
                     ³35  ³TS11, TU80 *2    ³   1   ³   4   ³
                     ³36  ³LPA11-K          ³   2   ³  10   ³
                     ³37  ³IP11/IP300 *2    ³   1   ³   4   ³
                     ³38  ³KW11-C           ³   2   ³  10   ³
                     ³39  ³RX11 *2          ³   1   ³   4   ³
                     ³39  ³RX211 *2         ³   1   ³   4   ³
                     ³39  ³RXV11 *2         ³   1   ³   4   ³
                     ³39  ³RXV21 *2         ³   1   ³   4   ³
                     ³40  ³DR11-W           ³   1   ³   4   ³
                     ³41  ³DR11-B *2        ³   1   ³   4   ³
                     ³42  ³DMP11            ³   2   ³  10   ³
                     ³43  ³DPV11            ³   2   ³  10   ³
                     ³44  ³ML11 *3          ³   1   ³   4   ³
                     ³45  ³ISB11            ³   2   ³  10   ³
                     ³46  ³DMV11            ³   2   ³  10   ³
                     ³47  ³DEUNA *2         ³   1   ³   4   ³
                     ³48  ³UDA50 *2         ³   1   ³   4   ³
                     ³49  ³DMF32            ³   8   ³  40   ³
                     ³50  ³KMS11            ³   3   ³  20   ³
                     ³51  ³PCL11-B          ³   2   ³  10   ³
                     ³52  ³VS100            ³   1   ³   4   ³
                     ³53  ³Reserved         ³   1   ³   4   ³
                     ³54  ³KMV11            ³   2   ³  10   ³
                     ³55  ³Reserved         ³   2   ³  10   ³
                     ³56  ³IEX              ³   2   ³  10   ³
                     ³57  ³DHV11            ³   2   ³  10   ³
                     ³58  ³DMZ32            ³   6   ³  20   ³
                     ³59  ³CP132            ³   6   ³  20   ³
                     ÃÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄ´
                     ³*1 A KL11 or DL11 used as a console,  ³
                     ³   has a fixed vector.                ³
                     ³*2 The first device of this type has a³
                     ³   fixed vector.  Any extra devices   ³
                     ³   have a floating vector.            ³
                     ³*3 ML11 is a Massbus device which can ³
                     ³   connect to a UNIBUS via a bus      ³
                     ³   adapter.                           ³
                     ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ
                       
Vector addresses are assigned on the boundaries indicated in the modulus column
of Table A-2.  That is, if the modulus is 10, then the first vector address for
that device must end with zero (XX0).  If the modulus is 4, then the first 
vector address can end with zero or 4 (XX0, XX4).

Vector addresses always fall on modulo 4 boundaries (XX0, XX4).  That is, a 
vector address never ends in any number but four or zero.  Consequently, if a 
device has two vectors and the first must start on a modulo 10 boundary, then, 
using 350 as a starting point, the vectors will be 350 and 354.

A.4   A System Configuration Example
------------------------------------
Table A-3 contains an example of a system configuration that includes devices 
with fixed addresses and vectors, and floating addresses and/or vectors.

Table A-4 shows how the device addresses for the floating address devices in 
Table A-3 were computed, including gaps.

                Table A-3.  CSR and Vector Address Example
                        ÚÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄ¿
                        ³Controller³Vector³  CSR   ³
                        ÃÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
                        ³ 1 UDA50  ³ 154  ³ 772150 ³
                        ³ 1 DZ11   ³ 300  ³ 760100 ³
                        ³ 1 UDA50  ³ 310  ³ 760354 ³
                        ³ 2 DHV11  ³ 320  ³ 760500 ³
                        ÀÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÙ

           Table A-4.  Floating CSR Address Assignment Example
            
                    ÚÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄ¿
                    ³         ³                   ³  Octal ³
                    ³Installed³  Device           ³ Address³
                    ÃÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄ´
                    ³         ³ DJ11          Gap ³ 760010 ³
                    ³         ³ DH11          Gap ³ 760020 ³
                    ³         ³ DQ11          Gap ³ 760030 ³
                    ³         ³ DU11          Gap ³ 760040 ³
                    ³         ³ DUP11         Gap ³ 760050 ³
                    ³         ³ LK11A         Gap ³ 760060 ³
                    ³         ³ DMC11         Gap ³ 760070 ³
                    ³    ---->³ DZ11              ³ 760100 ³
                    ³         ³               Gap ³ 760110 ³
                    ³         ³ KMC11         Gap ³ 760120 ³
                    ³         ³ LPP11         Gap ³ 760130 ³
                    ³         ³ VMV21         Gap ³ 760140 ³
                    ³         ³ VMV31         Gap ³ 760150 ³
                    ³         ³ DWR70         Gap ³ 760170 ³
                    ³         ³ RL11          Gap ³ 760200 ³
                    ³         ³ LPA11-K       Gap ³ 760220 ³
                    ³         ³ KW11-C        Gap ³ 760230 ³
                    ³         ³ Reserved      Gap ³ 760240 ³
                    ³         ³ RX11          Gap ³ 760250 ³
                    ³         ³ DR11-W        Gap ³ 760260 ³
                    ³         ³ DR11-B        Gap ³ 760270 ³
                    ³         ³ DMP11         Gap ³ 760300 ³
                    ³         ³ DPV11         Gap ³ 760310 ³
                    ³         ³ ISB11         Gap ³ 760320 ³
                    ³         ³ DMV11         Gap ³ 760340 ³
                    ³         ³ DEUNA         Gap ³ 760350 ³
                    ³    ---->³ UDA50 (QD21)      ³ 772150*³
                    ³    ---->³ UDA50 (QD21)      ³ 760354 ³
                    ³         ³               Gap ³ 760360 ³
                    ³         ³ DMF32         Gap ³ 760400 ³
                    ³         ³ KMS11         Gap ³ 760420 ³
                    ³         ³ VS100         Gap ³ 761440 ³
                    ³         ³ TU81          Gap ³ 761450 ³
                    ³         ³ KMV11         Gap ³ 761460 ³
                    ³    ---->³ DHV11             ³ 761500 ³
                    ³    ---->³ DHV11             ³ 761520 ³
                    ³         ³               Gap ³ 761530 ³
                    ³         ³ DMZ32         Gap ³ 761540 ³
                    ³         ³ CP132         Gap ³ 761600 ³
                    ÃÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄ´
                    ³     * Fixed address                  ³
                    ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ




                   ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                   ³ Appendix B  PROM Removal and Replacement ³
                   ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

B.1   Overview
--------------
This appendix provides instructions for replacing the QD21's firmware PROM.

B.2   Exchanging PROMs
----------------------
The QD21 firmware PROM is located in the socket at U44.  Pry the existing 
PROM from its socket using an IC puller or an equivalent tool.

The QD21 PROM is identified by the part numbers on top of the PROMs.  Place 
the QD21 PROM in socket U44.  Make certain that the PROM is firmly seated and
that no pins are bent or misaligned.  (If the two rows of PROM pins are too far
apart to fit in the socket, grasp the PROM at its ends using your thumb and 
forefinger and bend one of the pin rows inward by pressing it against a table
top or other flat surface.)

            PROM      PCBA
            Number   Location

             E65       U44

NOTE  Firmware Revision Level E and above requires that jumpers S-T be set IN.
      See Table 4-2 for QD21 Jumper Definitions and Factory Configuration.




                   ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                   ³ Appendix C  DISK DRIVE CONFIGURATION ³
                   ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

C.1  Autoconfigure (Type Code 2)
--------------------------------
Each ESDI drive is autoconfigured by using type code 2 in the NOVRAM
parameters.  By using type code 2, the drive is automatically configured for
maximum storage capacity with all relevant drive parameters obtained directly
from the drive itself.  The controller uses ESDI commands to obtain drive
information (drive must be connected and powered up) then calculates and
programs the drive for the required settings.

This procedure is performed for each MSCP on-line command from the host
software.  To allow the controller to program the drive for the correct number 
of sectors, each drive must have the PROGRAMMABLE SECTOR SIZE option
enabled.  If the drive does not support the PROGRAMMABLE SECTOR SIZE
option, physically set the number of sectors as indicated (using the LIST
KNOWN UNITS option) by using the appropriate jumpers or switches as
described in the drive technical manual.

C.2  Parameter Values (Type Code 1)
-----------------------------------
If you are required to manually input the NOVRAM drive parameters, select type
code 1. Type code 1 is used with drives that require split logicals (two 
logical drives per one physical), or to retain compatibility with a previously
formatted drive used on a different Emulex controller.

If you are using type code 1 values to retain compatibility, input the 
parameters used for the previously formatted drives.  To obtain the correct
values for split logicals (or reduced capacity drive), each physical drive 
initially needs to use a type code 2 value. Program the NOVRAM for type code 2,
connect the drive(s), and use the internal diagnostic option LIST KNOWN UNITS.
This displays the drive geometry information needed in programming the NOVRAM.

For values not displayed with the LIST KNOWN UNITS command, use the
default values in subsection 3.8, Drive Configuration Parameters.

Once you collect these values, change the NOVRAM to type code 1 for each
drive that requires manual configuration, then input the parameters using the
collected values.  You can mix type codes in the NOVRAM parameter if required.  
This means you can use autoconfigure (type code 2) for one or more physical
drives, and then use supplied values (type code 1) for the remainder of the
drives.

           Table C-1. DRIVE CONFIGURATION PARAMETER VALUES for QD21
           ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ
     PARAMETER                                 DRIVE NAME

                   (1)    (2)      (2)    (2)     (2)    (1)      (1)     (1)
                   CDC FUJITSU HITACHI MAXTOR  MAXTOR MAXTOR MICROPOLIS SIEMENS
               Wren III M2246E DK512-17 EXT4380 XT4380E XT-8760E 1350 1558 1300

Type Code             1     1        1       1       1      1(3)  1     1     1
Number of Units of
 this Type            1     1        1       1       1      1     1     1     1
Number of Sectors
 per Track           36    35       35      34      34     52    35    35    35
Number of Heads       9    10       10      15      15     15     8    15    12
Number of Cylinders 969   822      822    1224    1224   1632  1023  1224  1216
Number of Spare
 Sectors per Track    1     1        1       1       1      1     1     1     1
Number of Alternate
 Cylinders            2     2        2       2       2      2     2     2     2
Configuration Bits    6     5       13      13      13      4    14    14     8
Split Code            0     0        0       0       0      0     0     0     0
Starting Head Offset* -     -        -       -       -      -     -     -     -
Removable Media Flag  0     0        0       0       0      0     0     0     0
Gap 0 Parameter    2318  3093     2314    3086    3086   4374  2316  2316  3344
Gap 1 Parameter    2827  3084     2827    6682    6682   6168  2827  2827  4112
Gap 2 Parameter     521  3337     6384    3095    3095    534   521   521   526
Cylinder Offset*      -     -        -       -       -      -     -     -     -
Spiral Offset         0     0        0       1       1      0     1     1    11

  *  Used only if Split Code is not 0.
 (1) Hard-Sectored Format Only
 (2) Soft-Sectored Format Only
 (3) Type Code 2 may also be used for maximum capacity with a programmable 
     sector size jumper enabled on the drive.


C.3  Recommended Drive Options
------------------------------
When using a type code of 2, the QD21 attempts to program the sector size via
ESDI command.  Some drives require this option to be enabled via jumpers or
switches on the drive; check the drive manufacturer's manual for more
information.  If the drive is not programmable, the QD21 will use the number of
sectors defined by the drive switch settings.

C.3.1  Setting the Switches on the CDC Wren III
-----------------------------------------------
The CDC Wren III is shipped from Emulex with the switches set as indicated, so
that there are 36 sectors per track (hard-sectored) and the QD21 controls drive
spin-up.  If your Wren III was not purchased from Emulex, you may need to
change the switch settings (see Figure C-1).

         Table C-3.  CDC Wren III Switch Settings Hard-Sectored Format
                     ÚÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÂÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
                     ³SW1- ³ Position ³ Description     ³
                     ÃÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÅÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ´
                     ³ 1   ³  ON      ³ Spindle control ³
                     ³ 2   ³  OFF     ³ 36 sectors      ³
                     ³ 3   ³  ON      ³                 ³
                     ³ 4   ³  OFF     ³                 ³
                     ÀÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÁÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

To change the switch settings for WREN III drives not purchased from Emulex,
the front cover plate must first be removed.  Use a TORX (six-splined) TX-10
screwdriver (or a small, flat-bladed one) to remove the two screws from each
side of the drive.  Remove the cover plate and set the switches.

In some versions of this drive, the LED is attached to the front cover and 
there is a separate inner plate. Remove both plates after loosening the screws.

After setting the switches, replace the plate(s) and the screws.  If your 
version has the LED on the cover plate, take care that the LED wires are 
properly aligned with the two top openings.